4 Mounting
Inflowing medium
Product flow
12
approx. half a turn. This is sufficient to reach the recommended instal-
lation position.
In adhesive and viscous products, the surfaces of the tuning fork
should protrude into the vessel to avoid buildup. Therefore nozzles for
flanges and mountings bosses should not exceed a certain length.
Fig. 6: Adhesive products
If LEVEL SWITCH 8110 is mounted in the filling stream, unwanted
false measurement signals can be generated. For this reason, mount
LEVEL SWITCH 8110 at a position in the vessel where no disturbanc-
es, e.g. from filling openings, agitators, etc., can occur.
To make sure the tuning fork of LEVEL SWITCH 8110 generates as
little resistance as possible to product flow, mount the sensor so that
the surfaces are parallel to the product movement.
30 mm
(1.18")