CAUTION
Risk of injury Chemicals hazard.
▶ Check the foil pack holder for damage and soiling. Both pistons must move smoothly and easily in both
directions over the full length of their travel in the foil pack holder. Replace the foil pack holder if it is
damaged and/or badly soiled.
1. Press the release button.
2. Pull the piston rod back as far as they will go.
3. Fit the front end of the foil pack holder into the front locating lug.
4. Pull the foil pack holder on to the rear locating lug and swivel the foil pack holder up.
5. Screw the static mixer (mixing nozzle) onto the foil pack.
6. Push the foil pack into the foil pack holder.
7. Swivel the foil pack holder into the dispenser.
5.6
Inserting the cartridge
1. Press the release button.
2. Pull the piston rod back as far as they will go.
3. Fit the front end of the cartridge into the front locating lug.
4. Pull the cartridge on to the rear locating lug and swivel the cartridge up.
5. Screw the static mixer (mixing nozzle) onto the foil pack.
6. Swivel the cartridge into the dispenser.
5.7
Manually discarding the initial quantity of mortar
WARNING
Risk of injury Chemicals hazard.
▶ Never point the dispenser toward yourself or other persons. Begin dispensing mortar only after the
mixing nozzle has been screwed on. Incorrect use can lead to injury.
You must discard the initially dispensed volume of mortar every time the static mixer (mixing nozzle)
is changed.
The initially dispensed mortar is not suitable for use.
1. Set the dispensing mode selector switch to
2. Squeeze the trigger until the mixing nozzle is completely full.
3. Set the dispensing mode selector switch to the appropriate volume of mortar for discarding
Discard the amount of mortar stated in the instructions for the foil pack.
One click of the dispensing wheel corresponds to 1 ml.
4. Discard the initially dispensed volume of mortar.
6
Operation
Observe the safety instructions and warnings in this documentation and on the product.
6.1
Injecting mortar
For each new foil pack and each new cartridge and if the mortar has hardened inside the mixing
nozzle, always use a new static mixer (mixing nozzle).
1. Press the trigger.
2. Inject the mortar.
6.2
Removing the foil pack holder and foil pack
1. Set the dispensing mode selector switch to
*2330324*
4
.
6
.
2330324
5
7
.
English
21