Turn off the appliance
Switch off the appliance at the rotating knob.
Pull out the mains plug.
Indicator lamp "Ready for use" turns off.
After each operation
Filter dedusting
Pull the handle of the filter clean-off out several
times and reinsert it while the appliance is turned
off.
Empty the container
Lock parking brakes.
Illustration
Remove the pressure balancing at the upper end.
Pull the locks of the placement mechanics up.
Pull the push handle upward. The container is un-
locked and lowered.
Illustration
Pull the container out by the handle.
Empty the container.
Reinsert the container and lock it with the push
handle.
WARNING
Crush hazard. Never hold your hands be-
tween the dirt container and the interme-
diate ring or put them near the lifting
mechanism while locking. Lock the con-
tainer by pressing the sliding bow with
both hands.
Plug in the pressure balancing.
Cleaning the device
Vacuum and wipe the appliance inside and outside
with a damp cloth.
Storing the Appliance
Coil the mains cable and store it.
Wind the suction hose around the sliding bow.
Insert the floor nozzle and the suction pipe into their
respective holder.
Place the appliance in a dry room and secure it
from unauthorized use.
Transport
CAUTION
Risk of injury and damage! Observe the weight of the
appliance when you transport it.
Close the suction connection, see operating in-
structions.
Release the park brakes and push the appliance by
the push handle.
Grab the appliance by the chassis, not by the slid-
ing bow to load it.
When transporting in vehicles, secure the appli-
ance according to the guidelines from slipping and
tipping over.
Storage
CAUTION
Risk of injury and damage! Note the weight of the appli-
ance in case of storage.
This appliance must only be stored in interior rooms.
Care and maintenance
DANGER
First pull out the plug from the mains before carrying out
any tasks on the machine.
Dust extracting machines are safeguards for the pre-
vention or elimination of hazards defined in the regula-
tions of BGV A1.
–
In order to carry out maintenance work, the user
must disassemble, clean and service the unit, in so
far as this is possible without endangering mainte-
nance personnel and other persons. Suitable pre-
cautions include decontamination before the unit is
disassembled. Precautions must be taken for local
filtered forced air ventilation at the place where the
unit is disassembled, the cleaning of the mainte-
nance surface and suitable protection of the per-
sonnel.
–
The outside of the unit should be cleaned thorough-
ly and any harmful substances removed. Alterna-
tively, a sealed coating may be applied before the
unit is removed from the danger area. All unit parts
are to be considered contaminated when they are
removed from the danger area. To avoid distribu-
tion of the dust, you must take the appropriate
measures.
–
In the framework of maintenance and repair work
all contaminated objects that cannot be cleaned
satisfactorily must be disposed of. Such objects
must be disposed of in impermeable bags in ac-
cordance with the valid provisions for the disposal
of such waste.
–
During the transport and maintenance of the appli-
ance the extraction opening is to be closed with the
connection socket.
WARNING
Safety equipment for preventing hazards must be ser-
viced and maintained regularly. This means that the
manufacturer's staff or persons trained by the manufac-
turer must check the equipment for proper functioning at
least once a year, i.e. check for leaks, filter damage,
functioning of the controlling elements, etc.
ATTENTION
Risk of damage! Do not use detergents containing sili-
cone to clean.
–
No outside help is required for carrying out basic
maintenance and cleaning.
–
The appliance surface and the inside of the con-
tainer should be cleaned regularly using a damp
cloth.
DANGER
Risk due to dust hazardous to health. Always use dis-
posal clothing and P2 or higher breath-safe masks while
carrying out maintenance tasks (such as changing fil-
ters).
Exchanging the flat pleated filter
Note: 2 persons are required to remove the suction
head.
Release safety screws on the locks of the suction
head.
Release and remove the suction head.
Release and remove the filter cover.
Take out the flat folded filter.
Dispose off the used flat-folded filter in a dust-tight
bag according to the statutory provisions.
– 4
EN
13