Original user manual FUXTEC FX-GP1200/FX-GP1600/FX-GP1800_rev02
-
Open filling screw (8).
-
Fill with water via the filling screw up to the mark on the pump housing
- Screw in the filling screws again.
Switching on
1. Open all shut-off devices (valve, spray nozzle, water cock) in the pressure line.
2. Insert the plug of the mains cable into the power socket.
3. Switch on the pump at the on / off switch.
Important:
Danger of damage to the pump! A closed pressure line can result in damage to the
pump. Do not allow the pump to run against a closed pressure line.
Switching off
Switch the pump off at the on / off switch after use. Close all the shut-off devices in the
pressure line.
Important:
Danger of injury from hot water. After extended use against the closed pressure side
(> 10 min.), the water in the pump can become very hot and may escape
uncontrolled!
Disconnect the pump from the mains supply and allow the pump and
water to cool down.
been remedied!
The risk of injury from hot water can arise in the event of:
- Incorrect installation,
- Closed pressure side,
- Lack of water in the suction line, or
- Defective pressure switch
Procedure in case of overheating
1. Disconnect the pump from the mains supply and allow the pump and water to cool
down
2. Check the pump, installation and water level.
3. Put the pump into operation again only after all the faults have been remedied!
Put the pump into operation again only after all the faults have
20