All manuals and user guides at all-guides.com
or the backup material are not long enough to reach the
column, clamp them to the table. Failure to do this could
result in personal injury.
Note: for small pieces (A) that cannot be clamped to the
table, use a drill press vise (Optional accessory).
The vice (B) must be clamp or bolt (C) to the table to
avoid injury from spinning work and vise or tool break-
age.
Drilling a hole.
Make a dent in the workpiece where you want the hole,
using a center punch or a sharp nail. Before turning the
switch on, bring the drill down to the workpiece lining it
up with the hole location.
Turn the switch on and pull down on the feed handles
with onIy enough effort to allow the drill to cut.
FEEDING TOO SLOWLY might cause the drill bit to burn.
FEEDING TOO RAPIDLY might stop the motor, cause the
bett or drill to slip, tear the workpiece loose, or break the
drill bit.
When drilling metal, it may be necessary to lubricate the
tip of the drill with motor oil to prevent burning the drill
bit.
Maintenance
WARNING:
For your own safety, turn the switch off and remove plug
from power source outlet before any operation of mainte-
nance on our drill press.
Keep your appliance clean.
Be careful some household cleaning products and sol-
vents such as benzine, trichloroethene, chloride, ammo-
nium, etc., can damage plastic parts.
To avoid motor darnage, blow out or vacuurn frequently
this motor to keep drill press dust from interfering with
normal motor ventilation.
Power cord.
To avoid shock or fire hazard, if the power cord is worm or
cut, or damaged in any way, have it replace immediately.
Lubrication.
All of the ball bearings are packed with grease at the fac-
tory. No further lubrication is required.
Periodically lubricate the splines -grooves -in the spindle
and the rack.
To lubricate the splines, bring do~ the quill and ject the
grease into the spindle from the top of the pulley. Bring
the quill up and down a few times. To lubricate the rack,
bring down the quill and apply grease to the outer surface
of the quill. Bring the quill up and down a few times.
m Electrical connection
The installed electric motor is completely wired ready tor
operation.
35
BA td 13-16.indd 35
15.04.11 10:58