Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Care; Additional Accessories; Installation; Electrical Connection - Bosch MP 100 Installationsanleitung Für Die Fachkraft

Ems 2/ems plus
Vorschau ausblenden Andere Handbücher für MP 100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Installation

Technical Data
IP rating
For installation in heat
source
For wall-mounted
installation
Protection class
ID no.
Temperature of ball thrust test 75 °C
Degree of pollution
Table 6
°C
°C
20
14772
44
26
11500
50
32
9043
56
38
7174
62
Table 7
Electrical resistances of the supplied swimming pool
temperature sensor
2.3

Cleaning and care

▶ Wipe the casing with a damp cloth when necessary.
Never use aggressive or caustic cleaning agents for this.
2.4

Additional accessories

For detailed information about suitable accessories, refer to
the catalogue or Internet page of the manufacturer.
For a mixed swimming pool circuit:
– Mixing valve motor; connection to VC1 (follow the
technical documentation of the installed heat pump for
the correct positioning of the mixer)
– Swimming pool temperature sensor; connection to
TC1.
Installation of additional accessories
▶ Install the additional accessories in accordance with legal
regulations and the instructions supplied.
12
Is determined by the IP
rating of the heat
source
IP 44
I
Data plate ( Fig. 15 at
the end of document)
2
°C
5730
68
2488
4608
74
2053
3723
80
1704
3032
86
1420
3
Installation
WARNING:
Danger to life from electric shock!
Touching live electrical parts can cause an electric shock.
▶ Before installing this product: Disconnect the heat source
and all other BUS nodes from the mains voltage across all
poles.
▶ Before commissioning: Mount the cover ( Fig. 14 at end
of document).
3.1
Installation
▶ Install the module on a wall as shown at the end of the
document ( Fig. 3 to Fig. 5), or on a mounting rail
( Fig. 6).
▶ Remove the module from the mounting rail
( Fig. 7 at end of document).
▶ Install the swimming pool temperature sensor TC1
( Fig. 1 [3] at the end of the document) in a suitable
location ( Fig. 16 at the end of the document).
3.2

Electrical connection

▶ Observe electrical regulations and use at least cable
H05 VV-...
3.2.1 Establishing the BUS connection and temperature
sensor (extra-low voltage side)
▶ If the conductor cross-sections vary, use a junction box to
connect the BUS nodes.
▶ Switch BUS nodes [B] as shown at the end of the document
via electrical distribution box [A] in star ( Fig. 12) or via
BUS nodes with 2 BUS connections in series ( Fig. 16).
If the maximum total length of the BUS connections between all
BUS nodes is exceeded or the BUS system has a ring structure,
commissioning of the system is not possible.
MP 100 – 6721819201 (2020/02)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis