Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning / Maintenance; Cleaning & Maintenance - Lacor 69032 Gebrauchs- Und Instandhaltungsanleitung

Induktionskochgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
8.- Shut down
After using, please press the "ON/OFF" button, the induction cooker will stop heating.
The fan will stop running after 1 minute to cool the induction cooker down, then unplug the
cooker and clean the cooker body.

CLEANING / MAINTENANCE

1.- Please unplug the cooker before cleaning, after the ceramic plate isn't hot, you can start
cleaning.
2.- The dust around the air entry and air vent can be cleaned lightly with flexible dry cloth or a
flexible brush or cleaner.
3.- The slight dirt on the ceramic panel: please clean with soft wet cloth.
4.- The oily dirt: clean with soft wet cloth dipped in little toothpaste or neutral detergent and
clean with soft wet cloth until no residue exists.
Troubleshooting Guide
1.- Power cord replacement
If the power cord is damaged, please contact the relevant after-sale service agent, who will
dispatch personnel for the repair. For the purpose of your safety, please never replace it by
yourself.
2.- Trouble shooting
If an abnormality comes up, the induction hotplate will enter the protective state automatically and
display corresponding protective codes:
Error Message
E0
Cause: No cookware or the cookware is not suitable for the induction cooker.
Solution: Put the suitable cookware on the cooking zone.
E1
Cause: The device becomes too hot (e.g. due to blocked ventilation slots)
Solution: Clear/unblock ventilation slots. Let the device cool off for a few minutes; the
device is ready for operation afterwards. Contact the retailer in case the
error message remains indicated in the display after the device has cooled
off.
Cause: Parts are damaged (e.g. transistor)
Solution: Contact retailer.
E2
Cause: Overheating-protection was activated and the device switched off.
Solution: Remove the cookware from the hob. Let the device cool off for a few
minutes. The device is ready for operation afterwards.
E3
Cause: Temporary overvoltage, device became too hot.
Solution: Let the device cool off for a few minutes. The devices is ready for
operation afterwards.
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and damages to the
induction hotplate.
40

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis