ELECTRICAL DATA

Coils suitable for individual and block assembly.
Coil dimensions
Lenght (mm)
18
Approval code:
PD87
Ex ia IIC T6, assembly as individual device
PD91
Ex ia IIC T6, in block assembly
PE33
Ex ia IIC T5, assembly as individual device
PE34
Ex ia IIC T5, in block assembly
PE89
Ex ia IIC T4, in block assembly
Electrical connection:
JC09
Impressed single wires 0.2 mm2 (AWG 24)
JF79
Circular connector M8
JF80
Rectangular connector 2-pole
JF82
Rectangular connector 2-pole without protective collar
Overview table for use in temperature class T6
Max.permissible
Temp.
ambient temp.
class
range [°C]
-40 to +45
-40 to +40
-40 to +55
T6
-40 to +50
-40 to +45
-40 to +40
nOTE
12 - 01 ATEX 2173
Width (mm)
10
Assembly
Block
assembly
Indi-
vidual
The max. permissible power consumption depends on the max.
ambient temperature, the temperature class and the type of
assembly. These values can be taken from the above table.
Height (mm)
22
Max. permissible
Ignition
power consump-
protection
tion [W]
0,4
0,5
0,4
0,5
0,7
0,8
Mass (g)
10
Gas-
group
type
Ex ia
IIC