Herunterladen Inhalt Inhalt Diese Seite drucken

Responsibility Of The Operator; Ignition Hazards - WIKA 732.14.100 Betriebsanleitung

Manometer typ 7, ng 100 und ng 160 nach atex
Vorschau ausblenden Andere Handbücher für 732.14.100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2. Safety
The manufacturer shall not be liable for claims of any type based on operation
contrary to the intended use.

2.2 Responsibility of the operator

EN
The legibility of the marking must be observed during time in use but at least
during inspection periods of three years. If any harm of the legibility is found
please contact the manufacturer to renew the marking.
For the safety of the system, the operator is obliged to carry out an ignition source
and ignition hazard analysis. Refer to chapter 2.3 "Ignition hazards".
The responsibility for classification of zones lies with the plant manager and not
the manufacturer/supplier of the equipment.

2.3 Ignition hazards

Relevant identified ignition
hazards
Hot surfaces
Mechanically generated sparks
and hot surfaces
Stray electric currents, cathodic
corrosion protection
Static electricity
Exothermic reactions, including
self-ignition of dusts
6
Implemented protective measures
The actual surface temperature depends on the
application, i.e. on the medium temperature
Temperature range marking; T range marking
Observation of legibility of marking
Information given in operating instructions
Low contact speed
Restriction of vibration
Selection of suitable materials
Information given in operating instructions
Grounding via process connection required
Information given in operating instructions
No propagating brush discharge
All conductive parts bonded
Limitation of projected area of non-conductive
parts
Limitation of layer thickness of non-conductive
parts
Grounding via process connection required
Description of cleaning process
Information given in operating instructions
Provision of material data of the wetted parts for
the customer in order to avoid the use of critical
media
Information given in operating instructions
WIKA operating instructions pressure gauge model 7 per ATEX