Herunterladen Inhalt Inhalt Diese Seite drucken

Ravelli S 70 Bedienungs- Und Wartungshandbuch Seite 180

Inhaltsverzeichnis

Werbung

Temperature (automatic mode)
Automatic mode: When this function is activated, the stove automatically manages the 5 ducting levels.
To use automatic mode, two room temperature probes (optional) or external thermostats must be installed in the room to be ducted
to set the temperature of the room served by ducting, or else reading of the thermostat must be enabled, following the steps below.
MENU
USER
TECHNICIAN
MANUFACTURER
Press the
"Access to menu" key to
access the MENU screen
T. DUCT. REAR
ENABLE EXT.T
T. DUCT. REAR
ENABLE EXT.T
In automatic mode, the output of the stove and of the two fans are managed independently, so as to reach and maintain the set
temperature in the relative environment.
To exit the screen to go back to the DUCTED menu, press the "back" key once; to go back to the Home screen, press the
"back" key several times.
��
The connection of the relative room temperature probe to the ducting is carried out by connecting the two poles at the back
of the stove where there is a quick coupling identified by the writing "T.EXT".
Cubature
To optimise automatic mode, set the cubature difference (m
you may choose from three options:
= EQUAL: if the cubature of the two rooms is more or less the same;
+ REAR: if the cubature of the room with ducting is larger than the one with the stove;
+ FRONT: if the cubature of the room with ducting is smaller than the one with the stove;
this way the stove will distribute more output to the larger room.
MENU
USER
TECHNICIAN
MANUFACTURER
Press the
"Access to menu" key to
access the MENU screen
CUBATURE
+ FRONT
+ REAR
Use and maintenance manual S 70 - S 90 - SC 90
FEED SCREW LOAD
CHRONOTHERMOSTAT
Press the
"confirm" key
to access the
UTENTE [USER] screen
Press the
"increase/decrease" keys
to modify ducting temperature.
Press the key to save the
parameter and to go back to
the DUCTED MENU screen
) of the rooms during the installation stage.
3
FEED SCREW LOAD
CHRONOTHERMOSTAT
Press the
"confirm" key
to access the
UTENTE [USER] screen
Press the
"increase/decrease" keys
to modify the setting.
USER
DUCTED
SET AIR-PELLET
Press the
"confirm" key
to go to the item
CANALIZZATA [DUCTED].
Press the "selection" key to
go to the item
TEMPERATURE
T. DUCT. REAR
ENABLE EXT.T
Press the
"confirm" key
to go to the item
ABILITA T.EXT [ENABLE EXT.T].
Enabling is carried out
by pressing the "confirm" key
USER
DUCTED
SET AIR-PELLET
Press the
"confirm" key
to go to the item
CANALIZZATA [DUCTED].
Press the "selection" key to
go to the item CUBATURA
CUBATURE
[CUBATURE]
+ FRONT
+ REAR
Press the
"confirm" key
to confirm the new setting
EN
Rev.0 28/06/2021
Pag.47
DUCTED
MANAGEMENT
TEMPERATURE
VENTILATION
CUBATURE
VIEW STATUS
T. DUCT. REAR
ENABLE EXT.T
DUCTED
MANAGEMENT
TEMPERATURE
VENTILATION
CUBATURE
VIEW STATUS
CUBATURE
+ FRONT
+ REAR

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

S 90Sc 90

Inhaltsverzeichnis