INSTALLATION
Safety
INSTALLATION
8. Safety
Only a qualified contractor should carry out installation, com-
missioning, maintenance and repair of the appliance.
8.1

General safety instructions

We guarantee trouble-free function and operational reliability
only if original accessories and spare parts intended for the
appliance are used.
CAUTION Burns
- Only mount the appliance on a vertical wall that
is temperature-resistant to at least 85 °C.
- Maintain the minimum clearances to adjacent
objects.
Material losses
!
- Never install the appliance directly below a wall
socket.
- Ensure that the power cable is not in contact with
any appliance components.

8.2 Instructions, standards and regulations

Note
Observe all applicable national and regional regula-
tions and instructions.

9. Appliance description

9.1

Standard delivery

The following are delivered with the appliance:
- Wall mounting bracket (hooked into the appliance)
10. Installation

10.1 Minimum clearances

E 500-3000

10.2 Installing the wall mounting bracket

The appliance is intended for wall mounting using the wall
mounting bracket supplied. The appliance may only be in-
stalled horizontally.
Note
- The wall mounting bracket can be used as a tem-
plate for wall mounting. This ensures sufficient
clearance from the floor.
- Use a spirit level if the floor is uneven or sloping.
1
2
a a a
Unhook the wall mounting bracket from the appliance.
Place the centred wall mounting bracket horizontally on
the floor. Mark holes 1 and 2.
Lift up the wall mounting bracket so that its lower holes
match up with the markings you have just made on the
installation wall.
Mark holes 3 and 4 on the installation wall.
Drill the holes at the 4 markings.
Secure the wall mounting bracket with suitable fixing ma-
terials (screws, rawl plugs). With the vertical slots, you can
compensate for an offset fixing hole.
3
4
| 21