6.4.6.
K factors (in imp./l) for screw-ons
When the dimensions of your pipe are slightly different from
dimensions d and s given in the table, recalculate the K fac-
tor using one of the formulae in § 6.4.2.
measuring device inserted
material from which the pipe
is made
dn
100
110
125
150
180
200
250
300
350
400
Tab. 6.20 : K factors, external diameters and theoretical cross-sections of screw-ons
(L) : Long version of the sensor
K factor in imp/US gallon = K factor in imp/l x 3.785
1)
K factor in imp/UK gallon = K factor in imp/l x 4.546
24
8020, 8024, 8025
pVc
pp / pe
4,83 (L)
5,29 (L)
33,0 (L)
1)
1)
3,45 (L)
-
44,7 (L)
1)
2,55 (L)
1)
3,10 (L)
1)
63,7 (L)
1,67 (L)
1)
2,12 (L)
1)
1,08 (L)
1,37 (L)
1)
1)
0,80 (L)
1,07 (L)
1)
1)
-
0,63 (L)
1)
-
0,42 (L)
1)
-
0,30 (L)
1)
-
0,23 (L)
1)
8041, 8045
d
pVc
pp / pe
[mm]
30,4 (L)
-
52,1 (L)
137 (L)
78,8 (L)
197 (L)
116 (L)
290 (L)
147 (L)
-
347 (L)
-
510 (L)
-
705 (L)
-
931 (L)
English
Type S020
Technicaldetails
external diameters and theoretical
cross-sections
s
d
pVc
pVc
pe/pp
[mm]
[mm]
110
8,1
110
125
9,2
125
140
10,3
140
160
6,2
160
200
9,6
200
225
8,6
225
-
-
280
-
-
315
-
-
355
-
-
400
s
pe/pp
[mm]
10
11,4
12,8
14,6
18,2
20,5
25,5
28,7
32,3
36,4