Herunterladen Inhalt Inhalt Diese Seite drucken

Rohde ST 630 Bedienungsanleitung Seite 33

Vorschau ausblenden Andere Handbücher für ST 630:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Data logging
Data logging commences when a firing is started. Data logging finishes when the
firing is complete and when the kiln has cooled to 100°C. A file: LOGnnn.CSV
is created on the FLASH drive. The first file to be created will be LOG000.CSV.
Subsequent firings will generate LOG001.CSV up to LOG999.CSV. Only 1000 log
files are allowed. It is best to move the LOG files to another storage disk after just
a few firings - because it takes about 1 second to index each existing file on disk
before a new file can be created. For example, if there are files LOG000.CSV to
LOG100.CSV on disk there would be a delay of just over 100 seconds before
LOG101.CSV could be created and logging could be commenced.
The files created are in "Comma Separated Variable" (CSV) ASCII format and can
be directly imported into Microsoft Excel Spreadsheets.
Logging Interval
This can be adjusted over the range 5 to 300 seconds (default 60 seconds) using
parameter P50 with the controller in configuration mode (see chapter "Other Fea-
tures", section Parameter Configuration).
Log File Format
Year Month Day
2018
4
1
2018
4
1
2018
4
1
2018
4
1
2018
4
1
2018
4
1
2018
4
1
2018
4
1
2018
4
1
Hour
Min
Sec
Temp.
20
8
52
20
9
7
20
9
22
20
9
37
20
10
52
20
10
7
20
10
22
20
10
37
20
10
52
Kiln
Set
Amb.
Prog. Seg.
Point
Temp.
26.7
28
24
26.7
28
24.2
26.7
29.2
24
26.7
29.2
24
26.7
30.5
24
26.7
30.5
24
26.7
31.7
24
26.7
31.7
24
26.7
33
23.9
Status
7
1
Heating Ramp
7
1
Heating Ramp
7
1
Heating Ramp
7
1
Heating Ramp
7
1
Heating Ramp
7
1
Heating Ramp
7
1
Heating Ramp
7
1
Heating Ramp
7
1
Heating Ramp
33

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Rohde ST 630

Inhaltsverzeichnis