6
WARNING!
!
•
Do not route hose underneath drip pan.
EN
•
Do not route hose between space in bottom shelf and back panel.
•
Do not route hose over top of back panel.
•
Ensure all connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on any
hose connection.
•
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a fire.
•
Do not use enclosure to store excess hose, as there is a greater chance of the hose contacting a hot
surface, it may melt and leak causing a fire.
Technical Data
The following table lists input values for the appliance.
Main
Side (Infra red)
Side (Flame)
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with the following list.
Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table above. For
replacement, use only the regulator specified by the manufacturer.
www.napoleon.com
Burner
Orifice Size
I
#61
0.86mm
0.86mm
I
Gas Category
3B/P(30)
Orifice Sizes(see above)
I
Butane 30mbar
Gases / Pressures
Propane 30mbar
BE, BG, CY, DK, EE,
FI, Fr, GB, Hr, HU,
Countries
IS, IT, LT, LU, MT,
NL, NO, rO, SE, SI,
SK, Tr
(Gross) Heat Input
(Total)
II
I / II
#65
16.6 kW
#69
3.0 kW
#69
3.0 kW
I
I
3+(28-30/37)
3B/P(50)
I
II
Butane 28-30mbar
Butane 50mbar
Propane 37mbar
Propane 50mbar
BE, CH, CY, CZ, ES,
Fr, GB, Gr, IE, IT, LT,
aT, CH, DE, SK
LU, LV, PT, SK, SI
Gas Usage
(Total)
I / II
1208 g/hr
218 g/hr
218 g/hr
N415-0580CE-GB-DE Mar 30.20