ELECTRICAL CONNECTION 191PE4E
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400V/3N (230V/3 available on request) (see
attached wiring diagrams). Specify the cor-
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Remove the electrical equipment box (E).
5 - Fit the power supply cable into the cable gland
(F).
6 - Connect the circuit-breaker (A) to the terminal
board (G) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
7 - Tighten the cable gland (F).
Important
When connecting, take care to connect the
neutral and earth lines.
8 - Replace the electrical equipment box (E).
9 - Replace the control panel (D) and the knobs (B)
on completion of the operation.
rect voltage for your device; it cannot be
modified after purchase.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
A
E
- 19 -
B
C
C
D
IDM-39615102100.tif
G
F
IDM-39615102200.tif