F
G
WL525 / WL575
WL525 / WL585 Linear 22 Green Flame LS / RS
WL530 / WL580
Figure 10. Safety distances with protective sheaths.
Abbildung 10. Sicherheitsabstände mit den Schutzmänteln.
3.1.3. Safety Distances
Incorrect stone placement can cause the
surrounding structures to heat up to dan-
gerous temperatures even outside the safety
distances. The defined safety distances are valid
only when the stones have been placed as de-
scribed in section 2.5.
See figure 9 and 10
Ceiling: The minimum safety distance between
•
the stove and the ceiling (A).
Walls and benches made of inflammable
•
materials: The minimum safety distances to
inflammable materials: on either side (B), behind
the stove (C), in the front (D). Minimum safety
distance on the water container side in RS/LS
models (G).
F
C
D
B
RS / LS
Linear 22 Green Flame
Linear 22 Green Flame ES
F
B
D
B
C
D
70
70
500
70
70
500
70
70
500
3.1.3. Sicherheitsabstände
Durch eine falsche Stapelung der Steine
können die umgebenden Strukturen sogar
außerhalb der Sicherheitsabstände auf gefähr-
liche Temperaturen erhitzt werden. Die angege-
benen Sicherheitsabstände gelten nur, wenn die
Steine so platziert werden, wie in Abschnitt 2.5.
beschrieben.
Siehe Abbildung 9 und 10
Dach: Der Mindest-Sicherheitsabstand zwischen
•
Ofen und Dach (A).
Wände und Liegen aus brennbarem Material.
•
Mindest-Sicherheitsabstand von brennbaren
Materialien: auf beiden Seiten (B), hinter dem
Ofen (C) und davor (D). Der Mindest-Sicher-
heitsabstand auf der Seite des Wasserbehälters
(RS/LS-Modelle) (G).
F
C
B
All dimensions in
millimeters.
Alle Abmessungen
in Millimetern.
F
G
40
-
40
40
40
-
EN
DE
41