Contents
R-410A - General info ..........................................................
Safety procedures ................................................................
Dimensions and clearances...............................................
Technical data .......................................................................
Installation .............................................................................
Water connections ...............................................................
Electrical connections .........................................................
Connection of Auxiliary Accessories ..............................
System test .............................................................................
Unit protection devices ......................................................
Maintenace ............................................................................

R-410A - General info

This air conditioner adopts the new HFC refrigerant
(R410A) which does not destroy ozone layer.
R-410A refrigerant operates at 50%-70% higher pressures
than R-22. Be sure that servicing equipment and
replacement components are designed to operate with
R-410A.
R-410A refrigerant cylinders have a dip tube which allows
liquid to flow out with the cylinder in a vertical position
with the valve at the top.
R-410A systems should be charged with liquid
refrigerant. Use a commercial type metering device in the
manifold hose in order to vaporize the liquid refrigerant
before it enters in the unit.
As for other HFC, R-410A refrigerant is only compatible
with oils recommended by the compressor manufacturer.
A vacuum pump is not enough to remove moisture from
oil.
Oils absorb moisture rapidly. Do not expose oil to
atmosphere.
Never open system to atmosphere while it is under
vacuum.
When the system must be opened for service, break
vacuum with dry nitrogen.
Do not vent R-410A into the atmosphere.
Use this unit only for factory approved applications.
The capacity and unit code are stated on the nameplate
data.
All manuals and user guides at all-guides.com
Air / Water Cycle Heat Pump
Page
1
2
4
4
5
6
8
9
12
15
15
MODELS WITH HYDRONIC
INSTALLATION
SITING THE UNIT
WATER CONNECTIONS
ELECTRICAL CONNECTIONS
CONTROL WIRING (Optional)
POWER WIRING
FILLING THE SYSTEM
FLUSHING WATER AND AIR
CHECKING FOR WATER LEAKS
CONFIGURING AND CHECKING THE SYSTEM
CAUTION:
Do not leave system open to atmosphere any longer
than minimum required for installation.
moisture absorption.
MODULE
30AWH004HB
30AWH006HB
30AWH008HB
30AWH012HB
30AWH015HB
MODELS WITHOUT
HYDRONIC MODULE
30AWH004XB
30AWH006XB
30AWH008XB
30AWH012XB
30AWH015XB
30AWH