2. Design and function

2. Design and function
2.1 Overview
2.2 Signal clamping (not for MH-3-HY)
The output signal of a pressure sensor can be above the nominal maximum signal
value, if no signal clamping has been set. Likewise, the output signal can also be below
the nominal minimum signal value. This undefined condition can cause an error in
the machine (software) of the customer. Signal clamping limits the output signal to a
minimum or maximum value which is to be defined by the customer.
2.3 Diagnostic function
By means of the output signal, fault conditions can be detected and evaluated via
software. Thus it is possible to differentiate between permanent and temporary faults.
2.4 CDS system
All process connections are available with the CDS system. The diameter of the pressu-
re port is reduced in order to counteract pressure spikes and cavitation.
2.5 Scope of delivery
Pressure sensor
Operating instructions (for model MH-3-HY)
Cross-check scope of delivery with delivery note.
WIKA operating instructions, OEM pressure sensor, model MH-3
Electrical connection (depending on version)
Case
Process connection, spanner flats
Process connection, thread