LUBRICATION & MAINTENACE
Oil the tool before each use with 4 to 5 drops air tool oil, placed in the air inlet is sufficient.
Use proper air pressure and CFM rating listed for this tool.
Drain water from hoses and compressor tank.
Water in the air supply system damaged the tool and loss of power.
Clean or replace air filters at prescribed intervals from.

TROUBLESHOOTING

Probable Cause
Dirty or clogged air passages
Insufficient air supply
Air leakage
Worn / damaged wear & tear parts
Tool matching
ATTENTION
During operation safety goggles and gloves should always be worn to
guard against flying rust and chips.
Always wear hearing protection during operation this air tool for a longer time.

ENVIRONMENTAL PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging must be sorted, taken to a recycling point and
disposed of in an environmentally friendly manner.
DISPOSAL
Dispose of this product at the end of its service life in accordance with your
region's disposal regulations. Ask your local waste agency about recycling
measures.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
(Insufficient power)
Flush and lubricate tool, drain air tank and supply line
Increase line pressure, make sure compressor matches
tool's air pressure and consumption needs
Use Teflon tape at all fittings and joints.
Check tool for worn or damaged O-rings & seals.
Replace as necessary
Be sure you are using a tool suited for the sanding
requirements of the job at hand.