NOTES ON THE DOCUMENTATION

2
Notes on the documentation
2.1

Observe other applicable documents

∙ Observe absolutely all operating and installation
instructions enclosed with the product, for the various
parts and components of the system.
2.2

Storing documents

∙ Pass these instructions and all other applicable
documents to the system user.
The system user should retain these instructions so that
they are available when required.
2.3

Validity of the instructions

These instructions apply exclusively to:
Type overview
Product
Type designation
Electric back up heater
3

Description of the product

3.1

Product structure

3.1.1
Hydraulic station
1
3
8
2
B
C
D
A
24
Article number
6kw
0020143590
4
5
6
7
H
G
E
F
Key
1
Expansion tank
2
Safety valve
3
Pressure sensor
4
Temperature sensor
5
Electric heater
6
Air bleed
7
Drain tap
8
Three-way valve
A
Installation heating circuit inlet
B
Installation heating circuit outlet
C
Safety valve drain
D
Domestic hot water circuit outlet to the tank
E
Tank domestic hot water circuit inlet
F
Glycol water circuit inlet from heat pump
G
Glycol water circuit outlet to heat pump
H
Drain tap
3.2

Type designation and serial number

Data plate location:
Key
1
Data plate
The type designation and the serial number are shown on
the data plate.
1
0020166663_00 - 05/13 - Vaillant