Herunterladen Inhalt Inhalt Diese Seite drucken

End Barrier; Adjustable Guardrail; Lifespan, Periodic Inspections, Maintenance And Servicing; Lifespan - Tractel guard trac WP Installations-, Gebrauchs- Und Wartungsanleitung

Die geländer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32

7.4.2. End barrier

Follow the instructions at section 7.4.1.
DANGER: The openings between the
end guardrails and other structures
should be as small as possible, and nev-
er be over 120 mm.

7.4.3. Adjustable guardrail

Installation is identical to that of guard trac™
WP, see section 7.3.4.
8. Lifespan, periodic inspections,
maintenance and servicing

8.1. Lifespan

Tractel® guard trac™ WP or guard trac™ WPS
guardrail systems can be used on condition
that, from their date of manufacture onwards,
they are:
• Used normally, in accordance with the recom-
mendations given in this manual.
• Inspected periodically at least once a year by
a technician. On completion of this periodic
inspection, it must be recorded in writing that
the guard trac™ WP or guard trac™ WPS is
fit to be returned to service.
• Stored and transported in strict compliance
with the conditions indicated in this manual.
The results of the inspection must be en-
tered on the Inspection sheet that can be
found in the centre of this manual.
Fill in the date of the next annual in-
spection on the installation's identifica-
tion plate.
NOTE: Due to its high modularity, the
guard trac™ WP or guard trac™ WPS
is an easily replaceble system. If there is any de-
fect, it must be put out of service to prevent any
use, then contact Tractel® or an authorised ser-
vice provider to define the components to be re-
placed.
8.2 Post-installation, annual inspection
and maintenance
An inspection must be carried out after installa-
tion in compliance with the inspection sheet. Fill
in the date of the next annual inspection on the
installation's identification plate (fig. 19).
IMPORTANT: Tractel® or a competent
person should check the guard trac™ WP
or guard trac™ WPS guardrail every 12
months or every time the guardrail has prevent-
ed the fall of a person or object, and issue written
authorisation for continued use. Failing this, the
guardrail should be put out of service to prevent
any further use, and then be refurbished. This
inspection should be carried out in compliance
with the method defined by Tractel®.

8.3. Equipment service

DANGER: guard trac™ WP or guard
trac™ WPS guardrail servicing is man-
datory in the following cases:
1. In the event of an anomaly revealed during
inspection, whether annual or not (see sec-
tion 8.1), or as soon as an operating fault or
degraded state is noted.
2. When the guard trac™ WP or guard trac™
WPS has arrested a falling person.
3. When the guard trac™ WP or guard trac™
WPS shows abnormal deformation of com-
ponents.
4. When one or more counterweights show
signs of shearing (fig. 14) rough installation
surfaces or dirt.
5. When, during installation, you experience
difficulty in inserting parts (jamming of coun-
terweights, barriers or others).

9. Cases of prohibited use

It is forbidden:
1. To install guard trac™ WP or guard trac™
WPS guardrail without the proper author-
isation and competences or, failing that,
without the supervision of a person who is
authorised and competent.
2. To use the guard trac™ WP or guard trac™
WPS guardrail if any of the markings on any
components is missing or illegible (see sec-
tion 13).
3. To install or use any guard trac™ WP or
guard trac™ WPS guardrail that has not un-
dergone prior checks (see section 7.2).
4. To use a guard trac™ WP or guard trac™
WPS guardrail that has not been subject
GB
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Guard trac wps

Inhaltsverzeichnis