4. GANGWAY ENTRY ASSEMBLY
•
Attach the entry platform (ITEM 4) to the boiler platform (ITEM 1).
Pay attention to the entry platform assembly direction
Entry platform
ITEM 4
Position one HM8x25
screw + washers + M8 nut
for articulation
Attachment HM8x25
screws + washers + M8
nut
WARNING
Caution: do not release the entry platform sharply as this may damage the product. Perform
the operation safely.
Do not walk on the entry platform before the gangway is fully assembled: risk of falling
Attachment HM8x25
screws + washers + M8
nut
0NO0R0004-#
Platform +
boiler
Entry platform
ITEM 4
LRR gangway installation manual
Position one HM8x25
screw + washers + M8 nut
for articulation
Platform +
boiler
Entry platform
ITEM 4
Page 7 of 11