Herunterladen Inhalt Inhalt Diese Seite drucken

Dimensions And Weight - AER Compact Mobile 2 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Compact Mobile 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. Technische Daten
Power
Power amp
60 W / 4  (1% THD)
Monolithic IC with DMOS output
Dynamic range (A-weighted): 94 dB
Mains power
Mains voltage (depending on model):
100, 120, 230, or 240 V AC, 50–60 Hz
Power consumption: max. 240 W
Power consumption (only charging): 45 W
Mains fuse
Size: 5 x 20 mm
Rating:
For 230 and 240 V models: T 1 A L / 250 V
For 100 and 120 V models: T 2 A L / 250 V
Internal
Type and
2 rechargeable sealed lead-acid
battery
rating
Operating
ca. 3 – 4 h depending on
time
Recharge
100% full charge: ca. 16 h
time
90% full charge: ca. 12 h
Without output load.
Important
Charge batteries soon when empty.
Never store with empty batteries!
Recharge once a year when not in use.
The power switch must be ON in order to
charge the battery.
12 V DC
Input for operating the Compact mobile
connector
from an external 12 V battery
Max. current consumption: 10 A
1 = minus (–)
2 = plus (+)
This input can not be used to charge
Note:
the external battery from the Compact
mobile or to charge the internal battery
from an external power source.
General
Distortion
THD + N < 0.1% at 6 W / 4 
Analog signal
Subsonic filter, adaptive peak limiter
processing
Limiter
50 W / 4 
threshold
Speaker
8" (200 mm) dual cone full-range speaker,
system
bass reflex enclosure
Cabinet
12 mm (0.47") birch plywood
Finish
Waterbased acrylic, black spatter finish

Dimensions and weight

Dimensions
320 mm (12.8") high
326 mm (12.9") wide
282 mm (11.1") deep
Weight
13 kg (28.7 lbs)
batteries, each 6 V / 12 Ah
volume
NOTES
Rated conditions:
Nominal input voltage: 50 mV at input of channel 1.
Test signal: 1 kHz sine unless stated otherwise.
Signal voltages stated as RMS values.
0 dBV corresponds to 1 V RMS.
Gain of channel under test fully clockwise.
Tone controls in center position, colour off.
Master adjusted such that the rated output power is
obtained (requires that the limiter is disabled).
To avoid having to disable the limiter, master can be
adjusted such the rated output voltage at line out is
obtained instead.
Output voltages refer to rated conditions as stated above.
Min. input voltage: Input voltage required for rated output
power (limiter disabled) with gain and master fully
clockwise
Max. input voltage: Input voltage that does not cause more
than 1% THD+N, suitable control settings provided
THD + N: Total harmonic distortion + noise, with input and
output levels 10 dB below rated conditions.
Equivalent input noise voltage: Noise voltage at speaker
output divided by gain of amplifier. gain of input under
test fully clockwise, master fully clockwise, gain of unused
inputs minimal. Input shorted, B = 22 Hz ... 22 kHz
Residual noise: Noise of an output when its level control is
set to minimum.
Dynamic range (power amp): Ratio of rated output voltage
to residual noise voltage (master fully anticlockwise).
Options: The following options are available by internal
jumper settings.
1) Gain of microphone input can be reduced, resulting in
more headroom.
2) 9 V phantom power for channel 1 can be activated.
Caution:
Install only if required. Phantom power may
damage external equipment. Read the operating
instructions.
Specifications and appearance subject to change without
notice.
TD20121011
11

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis