Herunterladen Inhalt Inhalt Diese Seite drucken

Location Requirements; Electrical Requirements - Whirlpool WQ9 M2L Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 553

Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
To ensure proper ventilation for your refrigerator, allow for a
1.25 cm space on each side and at the top. Allow for a 5 cm
space behind the refrigerator. If your refrigerator has an ice maker,
allow extra space at the back for the water line connections.
When installing your refrigerator next to a fixed wall, leave a 9.5
cm minimum space between the refrigerator and wall to allow the
door to swing open.
NOTE: This refrigerator is intended for use in a location where
the temperature ranges from a minimum of 10°C to a maximum
of 43°C. The preferred room temperature range for optimum
performance, which reduces electricity usage and provides
superior cooling, is between 15°C and 32°C. It is recommended
that you do not install the refrigerator near a heat source, such as
an oven or radiator.
1.25 cm
12
9.5 cm

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
IMPORTANT: Installation and electrical connection must
be carried out by a qualified technician according to the
manufacturer's instructions and in compliance with the local
safety regulations.
The refrigerator is designed to operate on a separate
220-240 V, 10 A, 50-60 Hz circuit.
Make sure the voltage specified on the rating plate
corresponds to that of your home.
It must be possible to disconnect the appliance from the
power supply by unplugging it or by means of a main two pole
switch installed upstream of the socket.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection:
Recommended Earthing Method
220-240 V 50 Hz, 220 V 60 Hz, or 230/240 V 50 Hz AC only 10 A
fused and earthed electrical supply is required.
Type B
Type I
For Australia and New Zealand:
Your new appliance has been especially manufactured to meet all
Australian Standards and Conditions.
Some notations in the installation instructions may refer to
electrical requirements in other countries, so we draw your
particular attention to these specific notes.
Your appliance needs to be plugged into a 230/240 V 50 Hz AC
only 10 A earthed socket.
Type N
Type E and F
Type M
Type G