OPERATION INSTRUCTIONS (continued)
Set BOOST operating hours:
1. Press
button to unlock the keypad. with LED flashing, press
button to set the desired operating hours. Total of 4 settings: 36 hours,
48 hours, 60 hours and 00 (OFF). Keep pressing
the cycle.
2. With the desired hour value showing, press
keypad controls. The BOOST indicator will light up when activated.
The system is now starting more chlorine sanitizer production. After the boost procedure
has been completed, the system will automatically switch to the normal working mode.
The LED display will show the remaining BOOST hours first until it's finished and then
the remaining programmed saltwater system hours.
NOTE: If you forget to lock the keypad controls, the system will automatically lock it and
start working 10 seconds later.
3. To cancel the boost cycle, press
and reset the hour to "00".
Set electrode Self-Clean cycle time:
The default self-clean cycle time is 14 hours. To adjust the self-clean
cycle time:
1. Press
button to unlock the keypad and the LED display is
flashing. Depending on your pool water calcium hardness level,
press
button to select the self-clean cycle time as below. Total
of 3 settings: 14 hours, 10 hours and 06 hours.
Calcium Hardness
0 - 150 ppm
150 - 250 ppm
250 - 350 ppm
NOTE: The life of the cell varies depending on water conditions, pool usage and
operating time of the device. Select 14 hours cycle time to maximize the life of the
electrolytic cell if the calcium hardness level is up to 150 ppm. Manual routine cleaning
and maintenance will further lengthen the life of the electrolytic cell.
2. With the desired self-clean hours showing, press
and the LED display will return to the normal operating time. The system will reverse the
polarity of the electrode (7) every time according to the selected hours.
NOTE: If you forget to lock the keypad controls, the system will automatically lock it and
start working 10 seconds later.
SAVE THESE INSTRUCTIONS
(133IO) SaltwatEr SyStEm ENGlISH 7.5" X 10.3" PaNtONE 295U 07/21/2020
button to repeat
button to lock the
button to unlock the keypad, then press
Self-clean cycle time
Reverse polarity every 14 hours
Reverse polarity every 10 hours
Reverse polarity every 06 hours
button to lock the keypad controls