TECHNICAL DATA
Random Orbital Sander
Production code
Rated input
No-load speed
Orbital travel diameter
Dimensions of grinding plate
Weight according EPTA-Procedure 01/2014
Noise information
Measured values determined according to EN 62841. Typically, the
A-weighted noise levels of the tool are:
Sound pressure level (Uncertainty K=3dB(A)) 81,0 dB (A)
Sound power level (Uncertainty K=3dB(A))
Wear ear protectors!
Vibration information
Vibration total values (triaxial vector sum) determined according
to EN 62841
GB
Vibration emission value a
Uncertainty K=
WARNING!
The vibration emission level given in this information sheet has
been measured in accordance with a standardised test given in EN
62841 and may be used to compare one tool with another. It may
be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main
applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the
vibration emission may differ. This may significantly increase the
exposure level over the total working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or when
it is running but not actually doing the job. This may significantly
reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from
the effects of vibration such as: maintain the tool and the accesso-
ries, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings, instructions,
illustrations and specifications provided with this power tool.
Failure to follow all instructions listed below may result in electric
shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
English
6
6
EX 125 ES
4161 01 06...
4107 11 06...
... 000001-999999
300 W
7000-12000 min
2,4 mm ( 3/32")
125 mm
1,4 kg
94,0 dB (A)
7,4 m/s
2
h
1,5 m/s
2
SANDER SAFETY WARNINGS
Wear ear protectors. Exposure to noise can cause hearing loss.
Use protective equipment. Always wear safety glasses when
working with the machine. The use of protective clothing is recom-
mended, such as dust mask, protective gloves, sturdy non-slip
footwear, helmet and ear defenders.
-1
Always disconnect the plug from the socket before carrying out any
work on the machine.
The dust produced when using this tool may be harmful to health.
Do not inhale the dust. Use a dust absorption system and wear a
suitable dust protection mask. Remove deposited dust thoroughly,
e.g. with a vacuum cleaner.
Do not machine any materials that present a danger to health (e.g.
asbestos).
This machine is suitable only for dry sanding.
MAINS CONNECTION
Connect only to single-phase AC system voltage as indicated on
the rating plate. It is also possible to connect to sockets without an
earthing contact as the design conforms to safety class II.
Appliances used at many different locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Make sure the machine is switched off before plugging in.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
SPECIFIED CONDITIONS OF USE
This eccentric sander is a versatile machine. The following work can
be carried out with it: Coarse sanding and grinding, Fine sanding
and polishing, Rubbing down weather-beaten paint, Rubbing down
weather-beaten paint, Polishing up scratches on acrylic glass, Etc.
ELECTRONICS
In case of overload, the rotational speed is being reduced until
machine stops.
Please note that the machine will automatically accelerate back to
its original operating speed if the load is removed from it.

MAINTENANCE

Always disconnect the plug from the socket before carrying out any
work on the machine.
If the replacement of the supply cord is necessary, this has to be
done by the manufacturer or his agent in order to avoid a safety
hazard.
The ventilation slots of the machine must be kept clear at all times.
Use only AEG accessories and spare parts. Should components
need to be replaced which have not been described, please contact
one of our AEG service agents (see our list of guarantee/service
addresses).
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label
and order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße 10,
71364 Winnenden, Germany.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis