Herunterladen Inhalt Inhalt Diese Seite drucken

Homa Saniquick UF200 Originalbetriebsanleitung Seite 31

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Cut off the hose piece (D) on the appropriate length
(1-5). The correct number can be found in this list:
Pump
C(H)140
C(H)150
CR253
C(H)250
C(H)260
TP28
H307
H313
H328
4. Put the hose piece (D) on the discharge nozzle of your
pump and fix it with the hose clamp (C).
5. For TP28 and H3... only: to ensure venting, drill an 8mm
hole in the bottom of the coupling piece (B) as shown.
min. 1.000 mm
10
above OKFF
6. Insert the coupling piece (B) into the hose piece (D) as
shown and secure it with a hose clamp (C) as well.
7 . Place the pump in the sump. Make sure that the surfac-
es on the coupling piece are clean. Now insert the cou-
pling (B) into the receptacle (A) in the shaft and press
down the blue lever on the coupling piece (B). The blue
lever snaps firmly into the counterpart (A).
8. The pump connection line / float cable / pitot tube can
be led out of the tank via a branch
ventilation line (1). This must be positioned so that the
lower edge of the branch is at least 1,000 mm above the
upper edge of the finished floor (OKFF). The supplied ca-
(2)
ble gland
is used for odor-tight sealing.
Number
-
2
3
4
5
1
-
-
1
ø 8
Sewer backflow level
»
·
³
(3)
inserted into the
min. 1.000 mm
above OKFF
min. 1.000 mm
above OKFF
9. The pump connection cable must be sealed when it
exits the vent line. Use the cable gland provided for this
purpose.
Sewer backflow level
min. 1.000 mm
above OKFF
»
·
³
Sewer backflow level
¿
»
·
³
ENGLISH | 31