1 Introduction
This quick guide will assist you in starting up the unit. Follow
the safety notices or injury to health or property damage may
occur. Carefully read the original operating instructions in-
cluding information on maintenance and troubleshooting
prior to startup. These are located on the included CD and on-
line at
www.buehler-technologies.com
Please direct any questions to:
Bühler Technologies GmbH
Harkortstraße 29
40880 Ratingen
Germany
Tel.: +49 (0) 21 02 / 49 89-0
Fax: +49 (0) 21 02 / 49 89-20
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.
1.1 Intended use
This unit is intended for industrial use in gas analysis systems.
It's an essential component for conditioning the sample gas to
protect the analysis instrument from residual moisture in the
sample gas.
The device must not be operated in a zone 2, explosion class
IIC (ATEX, IECEx and EAC Ex) explosive gas atmosphere which
is rarely and only temporarily explosive, and in class I, divi-
sion 2 (US & Canada).
Optional installation of various add-on equipment may limit
the area of application of this device.
Coolers with Canada certificate and IECEx
The device must be installed in a lockable IP54 housing.
Coolers with USA certificate
The device must be installed in a lockable IP54 housing suit-
able for one or more class I division 2 wiring methods accord-
ing to National Electric Code (ANSI/NFPA 70).
Coolers with ATEX certificate
The device must be installed in an IP54 rated housing which
meets the requirements of EN 60079-15. The housing must re-
quire a tool which meets the requirements of EN 60079-0 and
EN 60079-15 to open.
Coolers with EAC Ex certificate
The device must be installed in an IP54 rated housing which
meets the requirements of Ghost 14254-2015.
Please note the specifications in the data sheet on the specific
intended use, existing material combinations, as well as pres-
sure and temperature limits.
BX440024 ◦ 12/2020
1.2 Type plate
Example:
Manufacturer and address
Type designation and voltage
TC-MIDI 230 V, 50/60 Hz, 290W
Serial no., item no.
101001081115 449631122111011001000
Certification markings
FM18ATEX0012X II 3 G Ex ec nC IIC T4 Gc
(Atex, IECEx and US/Canada)
IECEx FMG 18.0005X Ex ec nC IIC T4 Gc
USA/Canada: CL I DIV 2 GP ABCD
EAC Ex approval number
RU C-DE.HA65.B.00608/20
Description
0°C...60°C
Date of manufacturing
09/2018
1.3 Scope of delivery
• Cooler
• Product documentation
• Connection-/mounting accessories (optional)

2 Safety instructions

NOTICE
The device is suitable for hazardous areas.
This unit may only be used if:
• The product is being used under the conditions described
in the operating- and installation instructions, used ac-
cording to the nameplate and for applications for which it
is intended. Any unauthorized modifications to the unit
will void the warranty provided by Bühler Technologies
GmbH,
• The specifications and markings in the type plate must be
observed,
• The threshold values in the data sheet and the instruc-
tions must be observed,
• Monitoring equipment / protection devices must be con-
nected correctly,
• Service and repair work not described in these instruc-
tions are performed by Bühler Technologies GmbH,
• Genuine replacement parts must be used.
Erecting electrical systems in explosive areas requires compli-
ance with the following national regulations:
• IEC/EN 60079-14
• National electric code (NEC)
• Canadian electric code (CEC)
Additional national regulations pertaining to initial opera-
tion, operation, maintenance, repairs and disposal must be
observed.
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.
The equipment must be installed by a professional familiar
with the safety requirements and risks.
Be sure to observe the safety regulations and generally applic-
able rules of technology relevant for the installation site. Pre-
vent malfunctions and avoid personal injuries and property
damage.