For your own safety, fully comply with the assembly
instructions. All safety distances are minimum distances.
Installation of the insert must comply with the current rules
and regulations of the country where the product is installed.
Nordpeis AS is not responsible for wrongly assembled
inserts.
Subject to errors and changes.
For the latest updated version go to www.nordpeis.com.

2. Technical information

Inserts from Nordpeis all have secondary combustion
and are clean burning. The combustion takes place
in two phases: first the wood burns and then the
gases from the fumes are lit by the heated air. This
ensures that new inserts have minimal emissions of
soot particles and un-burnt gases (such as CO) and
are thus better for the environment. Clean burning
inserts require a small amount of wood to obtain good
heat output. Use exclusively clean and dry wood. We
recommend seasoned hardwood with a maximum
moisture content of 20%.
Insert
Material
Surface treatment
Weight of insert (kg)
Draught system
Combustion system
Combustion air
consumption (m³/h)
Operating range, Clean burn
(kW)
Heating area (m
)
2
Maximum fuel length (cm)
Flue outlet
Flue collar (*) (Ø mm)
*alternate versions exist due to national requirements
Flue gas temperature at flue
connector (°C)
Flue gas mas flow [g/s]
Draft at flue connector
recommended (Pa)
Data according to EN 13 229:2001 / A2:2004
Area of convection air vent
under insert (cm²)
Area of convection air vent
over insert (cm²)
Minimum distance conv. air
outlet to ceiling (mm)
Nominal heat output (kW)
Efficiency (%)
CO @ 13% O
(%)
2
22
Q-34AL
Steel
Heat resistant varnish
145
Air vent control
Clean burning
30
4-9
60-135
50
Top
Outer 150
328
6
>13
600
600
750
7
81
0,07
Flue gas temperature (°C)
Draft (Pa)
Fuel recommended:
Fuel length recomended
(cm)
Fuel charge (kg)
Refueling interval
(minutes)
Opening of the air vent
control (%)
Operation
* Intermittent combustion refers to normal use of a fireplace, i.e. new
wood is inserted when the previous load has burned down to ember
Warning: If the requirements for ventilation are
NOT complied with, the cooling airflow around
the product will be considerably reduced and
the product can overheat.
This can cause a fire.

3. Distance to combustible material

Firewall
Ensure that the safety distances are fulfilled.
(FIG 1).
When connecting a steel chimney to the top outlet use
the security distances required by the manufacturer.
Important! When placing the insert on
a combustible foor, a steel plate of at least 0.7mm
must cover the entire foor surface inside
the surround. Any fooring made of combustible
material, such as linoleum, carpets etc. must be
removed from underneath the steel plate.
The insert expands when in use, and for this
reason the surround must NEVER rest on the
insert, but have a gap of about 3 mm. The
insert must neither rest on the bench plate
or against the sides. It is recommended to
dry stack the surround in order to adjust the
insert prior to perforating the chimney for the
4. Assembly
Removing the insert from the pallet
Before the insert is removed from the pallet, remove the
accessories in the combustion chamber. To acess the
combustion chamber, do as follows:
1. Loosen the transport safety from the counterweight
and loosen the screw fastening the transport safety to
the product. Push the transport safety away from the
counterweight FIG 3a
GB
273
min. 12
Wood
50
1,4
45
35
Intermittent*