Herunterladen Inhalt Inhalt Diese Seite drucken

Trouble Shooting - Josef Kihlberg JK20T779 Betriebsanleitung

Druckluft-heftzange
Vorschau ausblenden Andere Handbücher für JK20T779:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8
Before all trouble shooting tasks on
the stapler it must first be
disconnected from the air supply.
No staples when firing the tool.
Inadequate power. The staples do not penetrate
the material sufficiently.
Noise level is too high.
Jammed staple in the nozzle.
05.20

TROUBLE SHOOTING

FAULT
ELIMINATION
Check that the right type of staples is being used
and moves easily inside the rail.
Always use Josef Kihlberg original staples.
Check if the feeder spring is not defective. If
necessary replace.
Check if the staple pusher is not defective. If
necessary replace.
Clean the staple track.
Air pressure too low. Secure that working pressure
is as recommend, see chapter 6.2
Adjust the air pressure as chapter 6.2
Has the tool been used without oil? Provide lubri-
cation, see chapter 5.2.
Fit a longer driver blade.
Check if the air pressure is correct. Adjust as per
chapter 6.2.
Ensure that the work piece is firmly held in place.
Vibration causes high sound levels.
Open the door and remove the defective staple,
see chapter 7.3.