4.2 Overview of the alarm messages in the dis-
play
An alarm message is displayed depending on the pres-
ent operating condition of the alarm control system:
With deactivated alarm control system: !!! CHECK !!!
With activated alarm control system: !!! ALARM !!!
If the alarm control system is activated, an alarm mes-
sage is only displayed after deactivation (chapter 3.5),
e. g.:
!!! ALARM 8 !!!
Z o n e 8
An alarm has been recorded in the alarm zone 8.
With deactivated alarm control system, a corre-
sponding message is immediately displayed:
!!!! CHECK !!!
Z o n e 7
In the alarm zone 7 the panic button (Panic*) has been
actuated, a smoke or fire detector (Fire*) activated, or
an emergency or fire door (Alert*) opened.
!!!! CHECK !!!
Mains Flt
The mains supply has been interrupted.
!!!! CHECK !!!
A l e r t
By simultaneously pressing the buttons 1 and 3 at a key-
pad controller, an internal alarm has been triggered.
If an anti-tamper contact has been opened, the fol-
lowing messages are possible:
!!!! CHECK !!!
Case Tamp
The anti-tamper contact of the alarm control system is
open.
!!!! CHECK !!!
KP Tamper
The anti-tamper contact of a keypad controller is open.
!!!! CHECK !!!
Bell Tamp
The anti-tamper contact of the alarm unit (or the siren
or strobelight) is open.
!!!! ALARM !!!
T a m p e r
One of the contacts in the common sensor anti-tamper
loop has been opened.
All manuals and user guides at all-guides.com
* programmed zone feature

4.3 Reading the log

In the log the last 64 events with date and time are
documented. Alternatively also 256 events without
date and time can be stored. This option can be pro-
grammed by the technician, if required.
1) The alarm control system must be deactivated.
Then the display shows e. g.:
28 Jun 14:37
<<<
UNSET
2) Enter a valid master access code (user numbers 1
to 3) with the numerical keys. The display shows:
Do You Want to..
Set User 1 ?
3) Press the button No within 15 seconds, otherwise
the menu will be exited. The display shows:
Do You Want to..
T e s t ?
4) Press the button No again. The display shows:
Do You Want to..
Delete Zone ?
5) Press the button No once more. The display
shows:
Do You Want to..
Select Options ?
6) Press the button Yes. The display shows:
Do You Want to..
Program Chime ?
7) Press the button No. The display shows:
Do You Want to..
Program Codes ?
8) Press the button No once more. The display
shows:
Do You Want to..
Set Date/Time ?
9) Press the button No once again. The display
shows:
Do You Want to..
View Log ?
10) Press the button Yes. The display now shows the
last event, e. g.:
28 Jun 06:50
Off User 1
The user 1 deactivated the alarm control system
on June 28 at 6.50 a.m.
11) With the button No it is now possible to display
previous events. In case of an alarm message
(date + "alarm"), after activating the button No
again, the alarm zone concerned is indicated.
>>>