Maintenance and Malfunction Treatment
1) The surface of the treadmill should be kept clean, pull out the power line before cleaning. You can clean
the running belt and the surface of the treadmill with a soft and wet cloth.
2) The running belt is adjusted at factory; it may runs defectively after transportation and use. Turn off the
treadmill before adjusting, pull the belt in the center, and then adjust the left and right bolts in rear roller with
hex spanner (See figure ) it is better to adjust 1/2 circle once. Then turn on the switch, check if the belt
10 runs defectively when the running speed is 4~5 km/h.
3) After using over 100hours or the lubricant between the running board and the running belt is used up,
please lubricate the running board and adjust the running belt well.
4) After a long time of running, the belt may be longer and stuck. You should turn the left and right adjustor
bolt in rear roller clockwise at same position till the runs smoothly and freely.
Warning:
1) The safety level of the equipment can be maintained only if it is examined regularly for damage and
wear, e.g. pins, connection points.
2) Please replace defective components immediately and/or keep the equipment out of use until repair.

Werbung