2.4
See type plate on the appliance.
3.
The appliance constantly keeps the water content avail-
able at the preselected temperature.
The DHW outlet temperature can be variably adjusted
at the temperature selector. The output is switched on
automatically as soon as the appliance temperature falls
below the selected value.
cess.
4.
4.1
You can select whichever temperature you require at the
temperature selector.
The ON/OFF indicator illuminates while the water is being
heated.
1 Temperature selector
Fully turned to the left „Frost protection"
„E" approx. 60 °C
Fully turned to the right approx. 80 °C
2 Indicator
4.2
The water heater is equipped with a frost protection stage.
For this, fully turn temperature selector to the left (cold). In
this position, the water heater is protected against frost.
The tap and the water line are not protected.
4.3
The appliance has an economy setting „E". At this setting,
minor scaling inside the appliance will occur.
4.4
5.
» Never use abrasive or corrosive cleaning agents. A
» Check the tap regularly. You can remove limescale
» Have the protective anode checked initially by a
» Have the electrical safety of the appliance regularly
-
-
» Have the safety valve regularly checked by a heating
6.
6.1
The appliance fails to
deliver hot water.
Water can only be
drawn at a reduced
rate.
Loud boiling noises in-
side the appliance.
2
Water drips from the
1
safety valve after
heating has stopped.
Where a contractor is required, they can remedy the fault more
quickly and effectively if you provide the following details from
the appliance type plate:
Operation - for users and contractors
deposits at the tap outlet using commercially availa-
ble descaling agents.
contractor will then determine the intervals at which it
must be checked thereafter.
checked by an electrician.
contractor.
The temperature se-
lector is set to "OFF".
There is no power.
The jet controller in
the tap is scaled up.
The appliance is
scaled up.
-
The safety valve is
scaled up or dirty.
EWH 15 mini U
E-NO.:
229731
F-NO.
. . . . -
. . . . .
Remedy
Switch the appliance
ON by turning the
temperature selector.
Check the fuse/MCB
in your fuse box/distri-
bution panel.
Descale or replace the
jet controller.
Have a contractor
descale the appliance;
contact customer
service.
Switch the appliance
OFF and depressurise
it, by isolating it from
the power supply
and shutting off the
water supply. Have a
contractor check the
safety valve; contact
customer service.
Made in EU
11