TECHNICAL DATA
Pressure dependence:
Long-term stability:
Gas exchange:
Ambient temperature:
Warm up time:
Response time:
Electrical connection:
Housing:
Dimensions:
Installation:
Protection class:
Protection type:
Standards:
Optional:
®
AERASGARD
RTM - CO
®
AERASGARD
RCO
- W
2
®
AERASGARD
RLQ - CO
AERASGARD
®
RFTM - CO
®
AERASGARD
RFTM - LQ - CO
Type ⁄ WG02
RTM - CO
- SD
2
R T M - C O 2 - S D - U
RCO
- W
2
R C O 2 -W
R C O 2 -W- D I S P L AY
RLQ - CO
- W
2
R L Q - C O 2 -W
R L Q - C O 2 -W D I S P L AY
RFTM - CO
- W
2
R F T M - C O 2 -W
R F T M - C O 2 -W D I S P L AY
RFTM - LQ - CO
- W
2
R F T M - L Q - C O 2 -W
R F T M - L Q - C O 2 -W DISP L AY 0...100 % r.H.
Outputs:
Equipment:
Note:
- W ⁄ RLQ - CO
- W ⁄ RFTM - LQ - CO
2
2
± 0.13 % ⁄ mm Hg
< 2 % in 15 years
by diffusion
0...+ 50 °C
approx. 1 hour
< 2 minutes
2
0.14 - 1.5 mm
, via screw terminals
plastic, material ABS, colour pure white (similar to RAL 9010), stainless steel V2A (1.4301) housing optional
98 x 98 x 33 mm (Baldur 2)
wall mounting or on in-wall flush box, Ø 55 mm, base with 4 holes,
for attachment to vertically or horizontally installed in-wall flush boxes for rear cable entry,
with predetermined breaking point for cable entry from top ⁄ bottom in case of plain on-wall installation
III (according to EN 60 730)
IP 30 (according to EN 60 529)
CE conformity, electromagnetic compatibility according to EN 61 326,
EMC Directive 2014 ⁄ 30 ⁄ EU, Low Voltage Directive 2014 ⁄ 35 ⁄ EU
display with illumination, two line, cutout approx. 36 x 15 mm (W x H),
for displaying actual humidity, actual temperature, air quality and / or the actual CO
- SD
Room temperature and CO
2
Room CO
sensor, Premium
2
- W
Room air quality (VOC) and CO
2
- W
Multifunctional room sensor
2
for humidity, temperature and CO
- W Multifunctional room sensor
2
for humidity, temperature, CO
Measuring Range
Humidity
Temperature
–
0...+50 °C
–
–
–
–
–
–
–
–
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...+50 °C
0 -10 V or 4...20 mA (selectable via DIP switches, selected variant applies for all outputs) –
Standard room sensor RTM - CO
W = changeover contact – Standard room sensor RTM - CO
This unit must not be used as safety-relevant device!
- W ⁄ RTM - CO
2
sensor, Standard
2
sensor, Premium
2
content, Deluxe
2
content and air quality (VOC), Deluxe
2
CO
VOC
2
(fixed)
0...2000 ppm
–
(switchable)
0...2000 ⁄ 5000 ppm
–
0...2000 ⁄ 5000 ppm
–
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
(switchable)
0...2000 ⁄ 5000 ppm
–
0...2000 ⁄ 5000 ppm
–
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
- SD with fixed output 0 -10 V!
2
2
11
- SD
2
content
2
Equipment
Item No.
Display
(Baldur 2)
–
1501-61B2-1001-200
W
1501-61A 0- 7301- 200
W
■
1501-61B0-7321-200
W
1501-61B1-7301-200
W
■
1501-61B1-7321-200
W
1501-61B6-7301-200
W
■
1501-61B6-7321-200
W
1501-61B8-7301-200
W
■
1501-61B8-7321-200
- SD without changeover contact !
Rev. 2019 - V29