INITIAL OPERATION

Check gate functionality manually when the drive has been
disengaged. Electrical operation is only possible with the control unit
that is supplied as standard.
Electrical connections: See control unit instructions.
Always ensure that the mechanical and electrical safety requirements
relevant to the given system are complied with. fig.7

MAINTENANCE WORK

The drive mechanics are maintenance-free. Check at regular
intervals (monthly) that the gate hardware and the drive are all firmly
in place. Disengage the drive and check gate functionality. Only an
easy-running gate will work well with a drive. A drive is no substitute
for a poorly functioning gate.
A sliding gate can also be secured by implementing on-site
measures (fence, wall, etc.). See fig.8.
709432F-en
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models HC100ML-2, HC500ML-2 Series
are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN13241-1
per the provisions & all amendments
of the EU Directives .............................................2006/95/EC, 2004/108/EC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener Models when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
B.P.Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
January, 2008
© 2008, Chamberlain GmbH

TECHNICAL DATA

HC100
Voltage IN
230Volt
Frequency
50Hz
Power
300W
Current rated
1.3A
Torque
9Nm
Capacitor
8µF
Therminal Overload
Protection
140
Travel Speed
12cm/sec
Duty Cycle
30
Working Temperatur
Range
-20
Protection Class
IP44
Degree of Protection
I
Weight
9
approx. Gate Length
5m
Max. Gate weight at
max. length (incl.
20% reserve)
300kg
conforms to the above Directives and Standard
HC500
230Volt
50Hz
360W
1.5A
10Nm
10µF
O
C
140
O
C
12cm/sec
30
O
C - 55
O
C
-20
O
C - 55
O
C
IP44
I
9
8m
500kg