Replacement Light
Ø
Max Power
33.2x120 mm
1,5 W
TROUBLESHOOTING
Problem
Light on, but motor does
not work
Both light and motor do
not work
Oil leakage
Vibration
Voltage
DC 12 V
Cause
The blades are blocked.
The capacitor is damaged.
The motor is damaged.
Apart from the above mentioned, check the following:
Light damaged.
Power cord loose.
Outlet and the air
ventilation entrance are
not tightly sealed.
The blade, if damaged,
can cause vibrating.
The motor is not tightly
fastened.
The cooker hood is not
tightly fixed.
ILCOS D
Picture
code
DSS-
1.5-S-33.2
/120
Solution
Check the blades.
Replace capacitor.
Replace motor.
Replace lights.
Connect the wires as the
electric diagram.
Take down the outlet and
seal with glue.
Replace the blade.
Fasten the motor tightly.
Fixed the cooker hood
tightly.
EN