Fault diagnosis
8.4

Troubleshooting in case of cascading

If an error occurs on TR4 safety switches used in a cascade, the related
device indicates the error state (Status/Diag LED flashes
switches off its safety outputs. In this case all other downstream TR4
safety switches also switch off their safety outputs and the Status/Diag
LEDs flashes
Green.
The safety switches ahead of a device with an error in the cascade can-
not detect the error state. Their Status/Diag LED continue to illuminate
Green if their actuators are in the response range.
Switch 1
Switch 2
Green
Actuator 1
Actuator 2
Switch 3
Switch 4
Green
Red
Actuator 3
Actuator 4
Operating Instructions
Red) and
Switch 5
Green
Green
Actuator 5