22
Installation
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burner.
3. With a socket spanner 7 remove the injectors and replace them with the ones which
are necessary for the type of gas you use (see table in Technical Data section).
4. Assemble the parts, follow the same procedure backwards.
5. Replace the rating label (it is near the gas supply pipe) with the one for the new type of
gas supply. You can find this label in the package supplied with the appliance.
If the supply gas pressure is changeable or different from the necessary pressure, you must
fit an applicable pressure adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the by-pass screw position. If you change from natural
gas 20 mbar to liquid gas, fully tighten the adjustment screw in. If you change from
liquid gas to natural gas 20 mbar, undo the by-pass screw approximately 1/4 of a turn.
Minimum adjustment screw
1
5. Make sure the flame does not go out when you quickly turn the knob from the maxi-
mum position to the minimum position.
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on the rating plate agree with the
voltage and the power of the local power supply.
• This appliance is supplied with a mains cable. It has to be supplied with a correct plug,
able to support the load marked on the identification plate. The plug has to be fitted in a
correct socket.
• Any electrical component must be installed or replaced by the Service Force Centre tech-
nician or qualified service personnel.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug after installation.
• Do not pull the mains cable to disconnect the appliance. Always pull the mains plug.
• The appliance must not be connected with an extension cable, an adapter or a multiple
connection (risk of fire). Check that the ground connection is in conformity with the
standard and regulations force.
1