EN
Adjustment of the Output
Configuring the analogue output as a voltage output:
• Set the rotary selector switch Ý to U / I MODE
è The red F-LED lights up
è The yellow U-LED lights up: Analogue output presently set to 0...10 V
è The yellow I-LED lights up: Analogue output presently set to 4...20 mA
• Briefly press the plus-key
è The Yellow U-LED lights up: Analogue output reconfigured to 0...10 V (voltage output)
• Set the rotary selector switch Ý to RUN
Configuring the analogue output as a current output:
• Set the rotary selector switch Ý to U / I MODE
è The red F-LED lights up
è The yellow U-LED lights up: Analogue output presently set to 0...10 V
è The yellow I-LED lights up: Analogue output presently set to 4...20 mA
• Briefly press the minus-key
è The yellow U-LED lights up: Analogue output reconfigured to 0...10 V (voltage output)
• Set the rotary selector switch Ý to RUN
Operate the sensor with high resolution (Resolution-Mode)
• Set the rotary selector switch Ý to RES. / SPEED-MODE
è The red F-LED lights up
è The yellow U-LED lights up: Sensor presently set to high speed
è The yellow I-LED lights up: Sensor presently set to high Resolution
• Briefly press the minus-key
The yellow I-LED lights up: Sensor now operates with high resolution.
• Set the rotary selector switch Ý to RUN
Operate the sensor with high speed (Speed-Mode)
• Set the rotary selector switch Ý to RES. / SPEED-MODE
è The red F-LED lights up
è The yellow U-LED lights up: Sensor presently set to high speed
è The yellow I-LED lights up: Sensor presently set to high Resolution
• Briefly press the plus-key
The yellow U-LED lights up: Sensor now operates with high speed.
• Set the rotary selector switch Ý to RUN
Sensors for your success
28
www.wenglor.com
Sensors for your success
www.wenglor.com