6) What to do if...
The manoeuvre does not start even by operating the T1
key on the card.
Make sure that the card is properly powered and that the fuse is not
blown. Between terminals 8 and 9 there must be mains voltage and
between terminals 10 and 11 you must read a continuous voltage of
approx. 24 Vdc.
No manoeuvres can be commanded and the led related to
the STOP input flashes rapidly.
It is possible that a short circuit has occurred and/or an overload on
the services output. The control unit has a fuse that automatically
resets, try switching off the power, wait a few seconds and switch it
on again.
The power supply voltages are correct, yet the manoeuvre
will not start
The Stop and Photo inputs must give their consent to activate the
manoeuvre: make sure that the LED corresponding to these inputs

7) Technical characteristics

Electronic control unit
Power supply:
on label)
Maximum motor power:
Command signal voltage:
Services (terminals 8-9):
Stop input:
Working time:
Pause time:
Operating temperature:
Dimensions / weight:
IP protection class:
Radio receiver
Frequency:
Coding:
Maximum number of transmitters that can be memorized:
Nice S.p.a reserves the right to modify its products at any time it deems necessary.

EC Declaration of conformity

EC Declaration of conformity with Directive 1999/5/EC
NOTES: The content of the present declaration corresponds to the latest
available revision, before the printing of the present manual, - of the document
registered at the head offices of Nice S.p.a.. The original text of this manual
has been readapted for publishing reasons.
Number: 241/A02; Revision: 0
The undersigned, Lauro Buoro, in the role of Managing Director, declares
under his sole responsibility, that the product:
Manufacturer's name: NICE s.p.a.
Address: Via Pezza Alta 13, Z.I. Rustignè, 31046 Oderzo (TV) Italy
Type: Control unit for single 230V ac motor.
Models: A02 - Accessories: Radio control series FLO, FLOR, Smilo
Conform with the requirements of the following EC directive:
• 1999/5/EC; DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND
COUNCIL of 9 March 1999 regarding radio equipment and telecommunica-
tions terminal equipment and the mutual recognition of their conformity.
According to the following harmonised standards: EN 300220-3
V1.1.1:2000,
8
are on. Make sure that dip-switches 3-4 correspond to the type of
input used. If it is a 8.2kΩ input the voltage between terminals 10-12
must be between 6Vdc and 18Vdc
You are unable to memorize a new transmitter.
Make sure that the type of transmitter is compatible with those
already stored in the memory. Switch the control unit off and then
back on, and check the flashing of the "radio LED" to see what type
of transmitters are already memorized.
The type of transmitter to be memorized is correct, but
you are unable to memorize it
Make sure that the card's receiving circuit operates properly: use a
functioning transmitter. If the control unit correctly receives a radio
code which is not, however, stored in the memory, it signals this con-
dition with a flash of the "radio LED". If you have already memorized
the maximum number of transmitters (254), this event is signalled by
6 flashes.
230 Vac 50/60 Hz or 120Vac 50/60Hz depending on the version (see value
600W for 230 Vac version; 400W for 120 Vac version
approx. 24Vdc
voltage 24Vdc ±30%; max current 50mA
configurable between NO, NC or 8.2kΩ +-25%
programmable from 5 to 120 seconds
programmable from 1 to 120 seconds or excludable
-20 ÷ 50 °C
128 x 112 x 43mm 350gr
44
433.92 MHz
FLO (fixed code), FLOR (rolling code) SMILO (rolling code)
254
The product also complies with the requirements of the following EC directives,
as amended by Directive 93/68/EEC of the European Council of 22 July 1993:
• 73/23/EEC; DIRECTIVE 73/23/EEC OF THE EUROPEAN COUNCIL of 19
February 1973 regarding the approximation of member state legislation relat-
ed to electrical material destined for use within specific voltage limits
According to the following harmonised standards: EN 60335-1:1994; EN
50366:2003,
EN 60335-2-95:2001 (as applicable), EN 60335-2-97:2000 (as applicable),
EN 60335-2-103:2003 (as applicable), EN 60950-1:2001 (as applicable)
• 89/336/EEC; DIRECTIVE 89/336/EEC OF THE EUROPEAN COUNCIL of 3
May 1989, regarding the approximation of member state legislation related
to electromagnetic compatibility
According to the following standards: EN 301 489-1:2004; EN 301 489-
3:2002
Oderzo, 2 January 2006
Lauro Buoro
(Managing director)