Herunterladen Inhalt Inhalt Diese Seite drucken

Operation - Dustcontrol DC 5900H Bedienungsanleitung

Asbest
Vorschau ausblenden Andere Handbücher für DC 5900H:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25

Operation

Connection
Filter cleaning
The filters should be cleaned when the manometer is in the red field.
1.
Keep the machine switched on and close the throttle at the cyclone inlet. Reset the filter cleaner button.
2.
Wait for 5-10 pulses.
3.
Switch off the machine.
4.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
5.
Switch on the machine.
6.
Check that the pressure gauge indicates green or that the filter indication lamp is off. If not, repeat the procedure. If the
gauge indicates red or the light is on even after repetition, the fine filter needs to be replaced.
Emptying
a – Container
The container underneath the cyclone should be emptied when about 2/3 full.
DC 5900H, Art.nr. 94380-B
19

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis