WARNINGS
This manual has been especially written for use by qualified fitters. No information given in this manual
can be considered as being of interest to end users. This manual is enclosed with control unit D703 and
may therefore not be used for different products!
Important information:
Disconnect the panel from the power supply before opening it.
ATTENTION: Capacitors C5, C6 and C7 located over the fuse "F1A" may be live even after the panel
has been disconnected from the mains supply. Short the 2 terminals of each with a screwdriver
before touching them.
The D703M control unit has been designed to control an electromechanical gear motor for automating
gates and doors of all kinds.
Any other use is considered improper and is consequently forbidden by current laws.
Please note that the automation system you are going to install is classifi ed as "machine construction"
and therefore is included in the application of European directive 2006/42/EC (Machinery Directive).
This directive includes the following prescriptions:
-
Only trained and qualified personnel should install the equipment;
-
the installer must first make a "risk analysis" of the machine;
-
the equipment must be installed in a correct and workmanlike manner in compliance with all the
standards concerned;
-
after installation, the machine owner must be given the "declaration of conformity".
This product may only be installed and serviced by qualified personnel in compliance with current, laws,
regulations and directives.
When designing its products, TAU observes all applicable standards (please see the attached declaration
of conformity) but it is of paramount importance that installers strictly observe the same standards when
installing the system.
Unqualified personnel or those who are unaware of the standards applicable to the "automatic gates
and doors" category may not install systems under any circumstances.
Whoever ignores such standards shall be held responsible for any damage caused by the system!
Do not install the unit before you have read all the instructions.

INSTALLATION

This product must be correctly installed by a qualified fitter. The maker declines all liability for damage
caused by incapacity or neglect.
In particular:
1. position the board vertically and as near as possible to the gear motor, taking care to keep the connec-
tion cables as short as possible;
2. make sure the cross-section of the power cables (power input, motors, earth and flashing light) is suf-
ficient for the absorption and length of the wires. The above also applies to the other cables used by
control and auxiliary devices;
To connect the power supply of control board in 400 V, use at least a 2.5 mm² cable, max.
40 m long.
3. make connections to the terminal board so as not to alter the level of protection offered by the con-
tainer which must be installed in a dry and protected place;
4. keep the power circuits separate from the control and auxiliary circuits, especially if the cables are long;
5. short any unused Normally Closed contacts.
The product must be properly earthed and the safety regulations in force in the country
of installation must be observed.
1. CONTROL PANEL FOR 230/400V AC SINGLE/THREE-PHASE MOTOR
MICROPROCESSOR-CONTROLLED LOGIC
INPUT STATUS LED'S