BAW M18MI-BLC50B-S04G
Inductive Distance Sensor
7
Interface (continued)
7.2
Device specification
Specification
Transfer rate
Minimum cycle time of device
Frame specification
– Amount of preoperate data required
– Amount of operate data required
– Enhanced parameters
IO-Link protocol version
Amount of process data from the device to
the master
Amount of process data from the master to
the device
Manufacturer ID
Device identification
Tab. 7-1:
Device specification
Process data cycle with 1.0 master
Tab. 7-2:
Device transfer times
7.3
Process data
The sensor outputs 3 bytes of process data via the IO-Link
interface.
Byte 0
7
6
5
4
3
2
Tab. 7-3:
Process data
7.4
Identification parameters
Name
Index
Vendor name
0x0010 (16)
Vendor text
0x0011 (17)
Product name
0x0012 (18)
Product ID
0x0013 (19)
Product text
0x0014 (20)
Hardware revision
0x0016 (22)
Firmware revision
0x0017 (23)
Application-specific tag 0x0018 (24)
Tab. 7-4:
IO-Link identification parameters
www.balluff.com
IO-Link Description
COM2
min cycle time
M-sequence capability:
– Preoperate M-sequence type
– Operate M-sequence type
– ISDU supported
Revision ID
ProcessDataIn
ProcessDataIn
Vendor ID
Device ID
Transfer times
Amount of PD x master cycle time = 4 x 3 ms = 12 ms
Byte 1
1
0
7
6
5
4
Reserved
Access
Length
R
7 bytes
R
15 bytes
R
21 bytes
R
7 bytes
R
28 bytes
R
3 bytes
R
8 bytes
R/W
Max. 32 bytes
Value
38.4 kBit/s
0x1E (3 ms)
0x1B
2 bytes
1 byte
Supported
0x11 (Version 1.1)
0x10 (3 bytes)
0x00 (0 bits)
0x378
0x020304
3
2
1
0
7
6
MSB
Analog value
Data type
Default
StringT
"BALLUFF"
StringT
"www.balluff.com"
StringT
"BAW M18MI-BLC50B-S04G"
StringT
"153938"
StringT
"Inductive distance sensor, 1...5 mm"
StringT
"1.00"
StringT
"1.01"
StringT
Not implemented
Byte 2
5
4
3
2
1
0
LSB
english
11