Gude Expert PDU Energy 8311 Serie Anleitung Seite 58

Vorschau ausblenden Andere Handbücher für Expert PDU Energy 8311 Serie:
Inhaltsverzeichnis

Werbung

Spezifikationen
{OFF=0|ON=1}
linesensor {line_num} {energy_sensor} events
show
linesensor {line_num} {energy_sensor} events ty-
pe set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5}"
linesensor {line_num} {energy_sensor} events ty-
pe show
linesensor {line_num} {energy_sensor} maxval set
{float}
linesensor {line_num} {energy_sensor} maxval
show
linesensor {line_num} {energy_sensor} minval set
{float}
linesensor {line_num} {energy_sensor} minval
show
linesensor {line_num} {energy_sensor} hyst set
{float}
linesensor {line_num} {energy_sensor} hyst show shows hysterese value for line meter
linesensor {line_num} {energy_sensor} publish
mode set {NONE=0|INTERVAL=1|
DIFFERENCE=2}
linesensor {line_num} {energy_sensor} publish
mode show
linesensor {line_num} {energy_sensor} publish
trigger set {float}
linesensor {line_num} {energy_sensor} publish
trigger show
linesensor {line_num} events set {OFF=0|ON=1}
linesensor {line_num} events show
linesensor {line_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5,EVT_DISPLAY=6,EVT_CONSOLE=7}"
linesensor {line_num} events type show
linesensor {line_num} maxval set {float}
linesensor {line_num} maxval show
linesensor {line_num} minval set {float}
linesensor {line_num} minval show
linesensor {line_num} hyst set {float}
linesensor {line_num} hyst show
modbus
modbus enabled set <off=0/on=1>
modbus enabled show
modbus port set <ip_port>
modbus port show
radius
radius {PRIMARY=0|SECONDARY=1} enabled
set <off=0/on=1>
radius {PRIMARY=0|SECONDARY=1} enabled
show
radius {PRIMARY=0|SECONDARY=1} server set
"<dns_name>"
radius {PRIMARY=0|SECONDARY=1} server
show
radius {PRIMARY=0|SECONDARY=1} password
set "{passwd}"
radius {PRIMARY=0|SECONDARY=1} password
hash set "{passwd}"
radius {PRIMARY=0|SECONDARY=1} auth ti-
meout set {num_secs}
radius {PRIMARY=0|SECONDARY=1} auth ti-
meout show
radius {PRIMARY=0|SECONDARY=1} retries set
{num}
radius {PRIMARY=0|SECONDARY=1} retries
show
radius chap enabled set <off=0/on=1>
radius chap enabled show
radius message auth set <off=0/on=1>
radius message auth show
radius default timeout set {num_secs}
Expert PDU Energy 8311
shows if events are enabled
enables different event types
shows what event types are enabled
sets maximum value for line meter
shows maximum value for line meter
sets minimum value for line meter
shows minimum value for line meter
sets hysterese value for line meter
sets publish mode
shows publish mode
sets trigger value for publish
shows trigger value for publish
LEGACY - enables events on/off
LEGACY - shows if events are enabled
LEGACY - enables different event types
LEGACY - shows what event types are enabled
LEGACY - sets maximum value for line meter
LEGACY - shows maximum value for line meter
LEGACY - sets minimum value for line meter
LEGACY - shows minimum value for line meter
LEGACY - sets hysterese value for line meter
LEGACY - shows hysterese value for line meter
enters cmd group "modbus"
enables Modbus TCP support
shows if Modbus is enabled
sets Modbus TCP port
shows Modbus TCP port
enters cmd group "radius"
enables radius client
show if radius client enabled
sets radius server address
shows radius server address
sets radius server shared secret
sets radius server crypted shared secret
sets server request timeout
shows server request timeout
sets server number of retries
shows server number of retries
enables CHAP
shows if CHAP is enabled
enables request message authentication
shows if request message authentication is enab-
led
sets default session timeout (when not returned as
L
L
L
L
L
L
L
L
L
L
58