If the scroll saw is switched on and the power supply in the mains
is interrupted, the scroll saw remains switched off, even if the
power supply is re-established. Press the "I" button to switch it on.
10.3 Work lamp operation (fig. 4)
1.
Press the on/off switch (21) to switch on and off the work
lamp (20).
10.4 Stroke rate controller (fig. 2)
The stroke rate controller (18) allows you to set the stroke rate ac-
cording to the material to be cut. In case of soft material, we recom-
mend high stroke rates, while strokes rates should be kept low for
hard material. Turn the stroke rate controller (18) clockwise to in-
crease the stroke rate. Turning anti-clockwise lowers the stroke rate.
10.5 Operating modes (fig. 1, 2)
The scroll saw is able to be operated manually or via the foot
pedal.
10.5.1 Manual controls
1.
Ensure that the machine is switched on.
2.
Set the operating mode selection switch (17) to the "M"
position to operate the saw manually.
3.
Use the stroke rate controller (18) to set the appropriate
stroke rate for the material (see 10.4).
10.5.2 Foot pedal controls
1.
Ensure that the machine is switched on.
2.
Set the operating mode selection switch (17) to the "F"
position to operate the saw via the foot pedal (7).
3.
The stroke rate may now be regulated via the foot pedal
position. If you depress the foot pedal (7) completely,
you will reach the maximum stroke rate.
CAUTION
When changing from foot pedal controls to manual controls,
the machine starts automatically. The stroke rate corresponds
with the stroke rate set on the stroke rate controller (18).
10.5.3 Stop position
If the operating mode selection switch (17) is set to the Stop
position (middle position), the machine stops.
CAUTION
The machine is not switched off in this position. When changing
from foot pedal controls to manual controls, the machine starts
automatically. The stroke rate corresponds with the stroke rate
set on the stroke rate controller (18).
10.6 Making inside cuts
This scroll saw allows inside cuts in workpieces without damag-
ing the outside or the circumference of the workpiece.
1.
Remove the saw blade (22) as described in 9.1.
2.
Drill a hole into the workpiece.
3.
Place the workpiece with the drilled hole over the open-
ing of the table insert (26) on the saw table (6).
4.
Install the saw blade (as described in 9.1) through the
drilled hole in the workpiece and set the blade tension.
5.
After completing the inside cut, remove the saw blade
(22) from the blade holders (as described in 9.1).
6.
Remove the workpiece from the table.
10.7 Mitre cutting (fig. 14)
WARNING
Be especially careful when making mitre cuts. The angle of the
saw table makes it easier for the workpiece to slip. There is a
danger of injury.
1.
To perform mitre cuts, adjust the distance between the
saw blade guard (5) which is mounted on the depressor
(24) and the work table accordingly.
2.
Swivel the table by loosening the knurled nut (14) and
tilting the saw table (6) into the desired position.
3.
3. Tighten the knurled nut (14).

11. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often damaged.
This may have the following causes:
• Passage points, where connection cables are passed through
windows or doors.
• Kinks where the connection cable has been improperly fas-
tened or routed.
• Places where the connection cables have been cut due to
being driven over.
• Insulation damage due to being ripped out of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used
and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regularly.
Make sure that the connection cable does not hang on the
power network during the inspection.
Electrical connection cables must comply with the applicable
VDE and DIN provisions.
Only use connection cables with the marking H 05 VV-F.
The printing of the type designation on the connection cable
is mandatory.
AC motor
The mains voltage must be 220-240 V ~ .
Extension cables up to 25 m long must have a cross-section of
1.5 mm
2
.
Connections and repairs of electrical equipment may only be
carried out by an electrician.