12. Additional functions
Button press:
Short press = <2 sec.
Long press = Press and hold >2 sec.
a) Access sub functions
Several measuring functions are assigned sub functions, and are marked in red around the function dial. Short press
the SEL button to cycle through each sub function.
b) Range
Pressing the RANGE button will switch the DMM from automatic "Auto" range to manual range.
This mode is only applicable with the following functions: V , V ,
• Enter manual range: Short press the RANGE button.
- "Auto" will disappear from the display.
- Short press RANGE to toggle through ranges (indicated by decimal position).
• Exit manual range: Long press the RANGE button or rotate the function dial, "Auto" will appear on the display.
c) Hold
The hold function keeps the indicated value on the display so you have more time to read or record it.
If you test live wires, make sure this function is deactivated before the measurement starts. Otherwise, the
measurement will not be correct.
• Short press the HOLD button to activate/deactivate the hold.
• The
symbol will appear to indicate that hold is active.
d) Peak
• This function allows users to capture faster signal events than the normal min/max function. Input changes of 1
millisecond or longer will be recorded.
• This mode is only available with the following functions: V , mV , µA , mA , and A .
• Long press the PEAK button to enter/exit peak value mode.
• Short press the PEAK button to cycle through "P-MAX" and "P-MIN" values.
Ω,
Hz, µA , mA , and A .