12.4.5 ProcessData Input Descriptor
The ProcessData Input Descriptor parameter describes the data format of the process data. Thus the master receives informa-
tion about the process data without IODD.
Index Sub-
Off-
Access
Index
set
Rights
0x0E
0
0
RO
Description of parameter values
Index name
ProcessData Input
Descriptor
12.4.6 ProcessData Output Descriptor
The ProcessData Output Descriptor parameter describes the data format of the process data. Thus the master receives inform-
ation about the process data without IODD.
Index Sub-
Off-
Access
Index
set
Rights
0x0F
0
0
RO
Description of parameter values
Index name
ProcessData Output
Descriptor
12.4.7 Vendor name
The manufacturer name can be read out in ASCII format with the Vendor name parameter.
Index Sub-
Off-
Access
Index
set
Rights
0x10
0
0
RO
12.4.8 Product name
The device name can be read out in ASCII format with the Product name parameter.
Index Sub-
Off-
Access
Index
set
Rights
0x12
0
0
RO
www.gemu-group.com
Length
Index name
3 byte
ProcessData Input
Descriptor
Parameter
Values
0x00
0x03
0x01
Length
Index name
3 byte
ProcessData
Output Descriptor
Parameter
Values
0x00
0x04
0x01
Length
Index name
5 bytes
Vendor name
Length
Index name
18 byte
Product name
Parameter
Bit offset
Type length
Data type -> BoolT
Parameter
Bit offset
Type length
Data type -> BoolT
Parameter
Parameter
83 / 112
12 Specific data IO-Link (pin 6)
Type
Values
ArrayT
0x00
0x03
0x01
Description
Type
Values
ArrayT
0x00
0x04
0x01
Description
Type
Values
StringT
"GEMUE"
Type
Values
StringT
"eSyStep Positioner"