Problem
Gate fails to operate.
Working distance of remote
control reduced.
Gate fails to stop at start or
end position.
Press open and close key of
motor, but can't working /
operate
1. When someone or obstructions between the gate, do not open or close the door to ensure safety.
2. The power supply for the control board should be equipped with a separate switch
with a fuse rated at 10AMP.
3. There is strong electricity in the control box. Please cut off the power supply before opening the
cover.
4. Motor gear modulus M = 4, number of teeth = 16, use the corresponding racks.
5. the gate should be as straight as possible, making sure after racks fixed good and the gate can be
in a good position with motor gear.
6. Racks and gear should be controlled in good gap. so can make sliding steady.
7. After confirming the direction of gate movement please check if the limit block fixed in good position
to avoid the motor run out of control due to failure.
Trouble Shooting
Possible causes
1. Check the clutch states, power-driven state or not?
2. Power no indication, and power trip.
3. The fuse has broken
4. Remote control failure or invalid
5. Damaged power cable
6. Remote control or motor problem
1. Low battery power or damaged
2. Interference from equipment using the same fre-
quency
3. The receiver of controller was damaged
1.The terminal stop toggle switch is damaged or obs-
tructed.
2. Limit switch of the motor and the limit detec
tion of the interface PCB board plug off.
3. Limit of open and close is in wrong position.
1. Blocked sensitivity is too high(set too big)
2. The gate has lifted off the track and disengaged the
drive gear from the rack

Important Notes

Repair method
> Recovery
> To restore power.
> Change the fuse.
> Detection or change.
> Detection and Repair.
> Detection and Repair.
> Replace battery.
> Wait / eliminate interference.
> Replace the control board.
> Replace toggle switch or remove
obstruction.
> Insert and fixed it.
> Adjust of limit switch(K1)
> Make blocked sensitivity lowered
and check gear and racks can operate
normally.
> Maintenance and replace.