The DC AirCube 500 has an electrical socket for 240 V, 1200 W.

Technical data

HxWxL [mm]
Weight [kg]
Inlet/Outlet [mm]
3
Max. flow [m
/h]
Power [W]
Pre-filter, "cartridge"
Area pre-filter and HEPA filter [m
Degree of separation, fine filter, EN 60335-2-69, Class
M [%]
Filter classification, EN 1822-1
Sound level [dB(A)]
Low speed
High speed
*/ Sound pressure level at 1.6 m height and 1 m distance according to DIN EN ISO 3744 in free field measurement at maximum
air flow.

Operation

The DC AirCube 500 has two-stage speed control. The DC AirCube 1200/2000 has variable speed control. This allows for
economical operation, for example during the night.
Connection
Overload protection. The machine is equipped with 3 overheating protections, one in the machine at 80°C that will reset after
cooling, one overheating protection in the fan at 90°C that is reset when the machine is made de-energized and a thermofuse
110°C at the soft start. In these situations, it is important to investigate the cause of the overheating. Turn off and disconnect the
power supply, and then wait for the machine to cool down (it can take up to 30 minutes).
DC AirCube 500
380 x 340 x 500
13
Ø125
500
230 V, 210
G4
2
]
0,18/4,56
99,995
HEPA 13
45
65
DC AirCube, Art.nr. 94178-G
DC AirCube 1200
DC AirCube 2000
869 x 430 x 550
1020 x 560 x 700
23
30
Ø250/315
Ø315
1060
1850
230 V, 385
230 V, 595
G4
G4
0,5/5
0,5/10
99,995
99,995
HEPA 13
HEPA 13
max 60 - 68
max 60-68
15