MEMOBOX 2 OPERATION (display - programming unit)
Explanation of buttons
P (1) - Advances data reading
(2) - Increments selected digit
† (3) - Decrements selected digit
S (4) - Selects digit to modify
R (5) - Memorizes selected data / Reset / Pass
Display of data
When MEMOBOX 2 is connected to the machine through the
serial connector, the display shows the sequence:
LaSan / Marco / Memo / Test- / Good- / Ready
The following sequence of data can be
displayed by pressing the P(1) button:
Dose 1
Cycle
Dose 2
Cycle
Dose 3
Cycle
Dose 4
Cycle
Dose 5
Cycle
Dose 6
Cycle
Dose M
Cycle
The - M
Cycle
The - 1
Cycle
The - 2
Cycle
Dec - 1
Cycle
Dec - 2
Cycle
Dec - 3
Cycle
Free 1
Cycle
Free 2
Cycle
Free 3
Cycle
Programming Code
To vary or program any data, the user must enter the access code 2322.
Setting the values
Press the P(1) button to select the data to modify.
Enter the programming code.
Press the S(4) button and the first digit on the right starts to flash.
Press the
(2) and † (3) buttons to set the desired digit.
Press the S(4) button to pass to the next digit.
When the setting is completed, press the R(5) button to confirm and store the data.
Resetting the cycles
To reset all the cycles of the different types of serving, enter the programming code and show 0 0 0 0 0 for the cycles of
serving 1. Press the R(5) button to start the Cycle Reset operation.
MEMOBOX 2 will display the message RESET DAY, after which the reset date can be entered.
Setting the functions
At the Prog- -Set index (Setting of Functions), it is possible to set three types of operation of the electronic control unit, each
independent of the others: GRINDER LOCK, WALLA COMPUTER, SERVING PROGRAMMING, by keying-in 1/0 in the
following positions:
Display
Downloaded from
www.Manualslib.com
F O R T H E U S E R
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
GRINDER-METERING UNIT with lock on (0 off)
WALLA COMPUTER on (0 off)
SERVING PROGRAMMING enabled (0 off)
manuals search engine
N = Number
Setup Number (Machine serial number)
Total Cycles
Prog- -Set- (Setup Functions)
Setup Day (Date of installation)
Reset Day (Date of last reset)
Calc. Day (Date of regeneration)
Calc. Cycle (Regeneration cycles)
Display
Button strip
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
NNNNN
47